Novel Method for More Precise Determination of Oscillometric Pulse Amplitude Envelopes
نویسندگان
چکیده
Curve fitting for oscillometric waveforms is vital to maximum amplitude algorithm (MAA) in blood pressure measurement. Popular methods in recent years, such as asymmetric Gaussian or Lorentzian functions, perform well when the profile of the oscillometric waveforms (OMW) are close to them. But they will have a relatively large mean square error (MSE) when the oscillometric pulse amplitude envelopes are not so regularly shaped. In this contribution, the artificial neural network (ANN) is implemented instead for the curving fitting. Aided by LabVIEW and MATLAB, its number of neurons in the hidden layer, weight initialization algorithm, training goal and learning algorithm are implemented or carefully considered after some necessary preliminary work. The experiment with 48 subjects ranging in age from 18 to 60 years is included in this research. The results show that the back propagation network with 11 neurons in the hidden layer, 0.0025 as training goal and Levenberg-Marquardt learning algorithm is well enough for the curve fitting. ANN with proposed optimum parameters is then compared with the asymmetric Gaussian/Lorentzian functions. After properly adjust the max epoch, ANN can finish computing the envelope in less than a second (3.3GHz CPU and 4GB RAM) in all of our experiments like the other two methods while its MSE is still much lower than the other two methods. Their performance in measuring blood pressure is also compared, and ANN shows greater robustness.
منابع مشابه
Oscillometric pressure pulse waveforms: their current and prospective applications in biomedical instrumentation
The objective of this paper is to describe current uses of oscillometric pressure pulse waveforms and to introduce several prospective applications of the waveforms. A specialized system (Carditor) for acquisition, processing and display of waveforms is described. Carditor was used to acquire a database of oscillometric blood pressure waveforms from a wrist cuff. The following prospective metho...
متن کاملA novel noninvasive and simple method for assessment of endothelial function: enclosed zone flow-mediated vasodilation (ezFMD) using an oscillation amplitude measurement.
BACKGROUND It is clinically important to estimate the degree of endothelial dysfunction. Several methods have been used to assess endothelial function in humans. Recently, we developed a new noninvasive method for measurement of vascular response to reactive hyperemia in the brachial artery, named enclosed zone flow-mediated vasodilation (ezFMD). The purpose of this study was to determine the v...
متن کاملEffects of intense laser pulse properties on wake field acceleration in magnetized plasma: Half-Sine Shape (HSS) and Gaussian Shape (GS) pulses
In this paper, we have simulated the excitation of wake fields in the interaction of an intensive laser pulses having Half-Sine and Gaussian time envelopes with a fully ionized cold plasma using particle in cell (PIC) method. We investigated the dependency of wake filed amplitude to different laser and plasma parameters such as laser wavelength, pulse duration and electron number density. In ad...
متن کاملPrecise Radar Target Ranging Estimation Based on Slip Matching of Envelopes
A novel precise radar target ranging method based on echo phases and slip matching of envelopes is presented in this paper. The method provides a high precision with rootmean-square error at sub-wavelength level, and it only requires envelopes of the echo pulses. The difficulty is matching procedure of envelopes. According to the principle of resolving ambiguous phases based on slip matching of...
متن کاملThe Value of a BP Determination Method Using a Novel Non-Invasive BP Device against the Invasive Catheter Measurement
OBJECTIVE The aim of this study was to evaluate the accuracy of a new blood pressure (BP) measurement method (Pulse method). METHODS This study enrolled 45 patients for selective percutaneous coronary intervention (PCI) via right radial artery. A BP device using either oscillometric (Microlife 3AC1-1) or Pulse method(RG-BP11)was used. At the beginning of each PCI, intra-radial BP was measured...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computer and Information Science
دوره 8 شماره
صفحات -
تاریخ انتشار 2015