Mechanical loosening of the stem in Charnley arthroplasties. Identification of the "at risk" factors.

نویسندگان

  • V Pacheco
  • P Shelley
  • B M Wroblewski
چکیده

A retrospective review of 72 cases of Charnley low friction arthroplasty revised for stem loosening, has identified a number of "at risk" factors. These were: previous hip surgery and, in radiographs taken at one year, demarcation of the distal cement and fracture of the cement near the tip of the stem. Separation of the back of the stem from the cement, as an isolated feature, was not considered significant. Endosteal cavitation of the femoral shaft, rare in the first year, indicated loosening of some duration. Patients whose radiographs show the "at risk" changes, should be followed-up indefinitely in order to plan timely revision and avoid gross loss of the femoral bone stock.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wear of the cup in the Charnley LFA in the young patient.

Since wear and loosening of the ultra-high-molecular-weight polyethylene cup are factors which limit the life of an arthroplasty we have attempted to identify factors associated with either low wear (0.02 mm/year or less) or high wear (0.2 mm/year or more). In a series of 1434 Charnley low-friction arthroplasties (1092 patients) 190 (13.2%) showed low wear while 149 (10.4%) showed high wear. We...

متن کامل

Stem fixation in the Charnley low-friction arthroplasty in young patients using an intramedullary bone block.

We report a prospective study of the use of intramedullary bone blocks to improve the fixation of a matt-finish femoral stem in Charnley low-friction arthroplasties. There were 379 patients (441 hips), but at a minimum follow-up of ten years there were 258 arthroplasties in 221 patients including some which had been revised. The mean age at surgery was 41 years (17 to 51) and the mean follow-up...

متن کامل

Radiological factors influencing femoral and acetabular failure in cemented Charnley total hip arthroplasties.

We have made a retrospective review of 185 cemented Charnley total hip arthroplasties performed between 1970 and 1974 to determine the relationships between radiological variables and failure of the femoral and acetabular components. We measured the acetabular wear, the orientation of the cup, the thickness and consistency of acetabular and femoral cement mantles, radiolucency and femoral align...

متن کامل

Predictors of early stem loosening after total hip arthroplasty: a case-control study.

PURPOSE To evaluate the influence of patient characteristics on stem loosening after cemented or uncemented total hip arthroplasty (THA) using a matched case-control study. METHODS; Consecutive records of 4372 cemented (716 cases and 3656 controls) and 809 uncemented (115 cases and 694 controls) primary THAs between 1981 and 2003 in 30 hospitals in 8 European countries were reviewed. Cases and ...

متن کامل

Migration and wear of long-term successful Charnley total hip replacements.

We analysed in-vivo migration and wear over a long period of all-polyethylene acetabular cups which had not been affected by mechanical loosening. The selection criteria of regular radiological follow-up, good clinical outcome (Charnley score of 5 or 6), continued walking without crutches and no radiological signs of loosening of the acetabular cups were fulfilled by 25 Charnley total hip arthr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 70 4  شماره 

صفحات  -

تاریخ انتشار 1988