Dry-reagent strips for measuring phenytoin in serum.

نویسندگان

  • R Sommer
  • C Nelson
  • A Greenquist
چکیده

A new reagent strip has been developed for measuring phenytoin in serum or plasma. It utilizes the chemistry of the Apoenzyme Reactivation Immunoassay System (ARIS) and is designed for use with the Seralyzer reflectance photometer. The 90-s test relies on comparison of strip reactivities with a two-point calibration line, which can be validly stored in the instrument for two weeks. Within-run CVs for controls at five concentrations ranged from 2.7 to 5.6%, between-run CVs from 2.3 to 6.3%. Phenytoin values obtained for clinical serum samples correlated well (r greater than 0.99) with those obtained by liquid chromatography or substrate-labeled fluorescent immunoassay. The speed and convenience of this assay for monitoring phenytoin in serum make it well suited for decentralized test sites such as emergency rooms, urgent-care centers, and physician's offices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simple adaptation of a radioimmunoassay kit for serum cortisol used to measure salivary cortisol.

Drug immunoassays with use of reagent strips have been introduced by the Ames Co. for theophylline and phenytoin assays. Their phenobarbital assay is based on the ais (Apoenzyme Reactivation Immunoassay System) principle. Thirty microlitres of diluted serum is applied to the reagent pad and the strip is read in the Seralyzer reflectance photometer after 85 s. Fifty-three serum samples assayed b...

متن کامل

Adaptation of Prostatic-Group-Label Homogeneous Immunoassay to reagent-strip format.

The Prostatic-Group-Label Immunoassay (PGLIA) technique has been incorporated into a reagent-strip format. We report use of flavin N6-(N'-2,4-dinitrophenyl-6-aminohexyl)adenine dinucleotide (DNP-FAD) as the prosthetic group derivative and 6-N-(2,4-dinitrophenyl)aminohexanoic acid (DNP-caproate) as the competing ligand. DNP-FAD not bound by antibody combines with glucose oxidase apoenzyme, which...

متن کامل

Use of the Reflotron system for cholesterol assay in capillary blood, venous blood, and serum--evaluation of accuracy and lot-to-lot reagent comparability.

Since its recalibration in 1987, the Reflotron "dry-chemistry" cholesterol method can produce accurate results. Here we report how cholesterol concentrations in venous blood, plasma, and serum determined with Reflotron compare with values determined for fingerstick samples. When no EDTA is used in the latter, accurate results may meet the WHO/CDC criterion of a maximum bias less than or equal t...

متن کامل

Test-strip method for measuring lactate in whole blood.

We have developed a dry reagent strip system for measuring lactate in whole blood. The test strip contains lactate oxidase (no EC number assigned), horseradish peroxidase (EC 1.11.1.7), and N-ethyl-N-(2-hydroxy-3-sulfopropyl)-m-toluidine. The system is designed to measure with a reflectometer the color that developed in the test strip, although the lactate concentration can be estimated without...

متن کامل

Dry-reagent strips used for determination of theophylline in serum.

A reagent strip for quantifying theophylline in serum or plasma has been developed for use with the Apoenzyme Reactivation Immunoassay System (ARIS) with the Ames Seralyzer reflectance photometer. The test takes 80 s and involves comparison with a two-point calibration line, which can validly be stored in the instrument for two weeks. Results for theophylline in clinical serum samples correlate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 32 9  شماره 

صفحات  -

تاریخ انتشار 1986