Comparison of Internal and Total Optical Aberrations for 2 Aberrometers: iTrace and OPD Scan
نویسندگان
چکیده
PURPOSE To compare and evaluate the total and internal aberrations measured by two aberrometers: the laser ray tracing aberrometer (iTrace, Tracey Technology) and the automatic retinoscope aberrometer (OPD Scan, Nidek). METHODS A total of 54 healthy eyes were enrolled in the study. Following pupil dilation, aberrations were measured with the iTrace and OPD Scan. We compared the aberrations obtained from measurements obtained at pupillary diameters of 4 mm and 6 mm with the OPD Scan and iTrace. Aberrations of internal optics and total aberrations were compared for the two aberrometers. For each aberrometer and each eye, the averaged Zernike data were used to calculate various root-mean-square (RMS) data. These parameters, together with the refractive parameters, were then analyzed and complimented by paired t-tests. RESULTS At a pupil diameter of 4 mm, the number of total aberrations in the entire eye showed significant differences for the mean values of spherical aberrations (Z4,0) obtained with the OPD Scan and iTrace aberrometers (p=0.001). Aberrations of the internal optics showed significant differences in the mean values of total RMS, coma (Z3,-1), and trefoil (Z3,3) between the iTrace and OPD Scan (p<0.001, p=0.01, p<0.001) for the same pupil diameter of 4 mm. At a pupil diameter of 6 mm, the two instruments showed a similar number of total aberrations. Aberrations of the internal optics showed significant differences in the mean values of total RMS, spherical aberration (Z4,0), and coma (Z3,-1) between the two devices (p<0.001, p=0.01, p<0.001). CONCLUSIONS The iTrace and OPD Scan showed the largest number of differences for aberrations of internal optics rather than total aberrations for both pupil diameters. These results suggest that in healthy eyes, the two aberrometers may vary in some details. The aberrometers showed more agreement at a pupil diameter of 6 mm compared to 4 mm.
منابع مشابه
Evaluation of the comparability and repeatability of four wavefront aberrometers.
PURPOSE To compare total ocular aberrations and corneal aberrations identified with four different aberrometers and to determine the repeatability and interobserver variability. METHODS In this prospective comparative study, 23 healthy subjects underwent bilateral examination with four aberrometers: the Irx3 (Hartmann-Shack; Imagine Eyes, Orsay, France), Keratron (Hartmann-Shack; Optikon, Rom...
متن کاملHigher order aberrations using the NIDEK OPD-Scan and AMO WaveScan.
PURPOSE To compare higher order aberrations measured with the NIDEK OPD-Scan and AMO WaveScan. METHODS Third- to sixth-order higher order aberrations were measured in 1072 eyes using the OPD-Scan and WaveScan. Means, standard deviations, confidence intervals, limits of agreement, and intraclass correlation coefficients (ICC) were calculated. RESULTS Aberrations of greatest magnitude with th...
متن کاملPrecision and agreement of higher order aberrations measured with ray tracing and Hartmann-Shack aberrometers
BACKGROUND To assess the precision and agreement of measurements of higher order aberrations (HOAs) obtained with a ray tracing aberrometer (iTrace) and a Hartmann-Shack aberrometer (Topcon KR-1 W). METHODS Prospective evaluation of the diagnostic test. Data from the right eyes of 92 normal subjects obtained using the two devices were included in this study. Two observers performed 3 consecut...
متن کاملPrecision of NIDEK OPD-scan measurements.
PURPOSE To evaluate the repeatability of wavefront measurements using the NIDEK OPD-Scan. METHODS A total of 179 eyes from 90 healthy volunteers (57 women and 33 men) with no corneal or lenticular pathology and normal visual acuity were enrolled in this study. Mean patient age was 39 years (range: 17 to 85 years). All patients underwent four consecutive measurements by one examiner with the N...
متن کاملInterpretation of aberrometry measurements in cataract surgery.
PURPOSE To discuss the use of wavefront measurements generated from the NIDEK OPD-Scan II and OPD-Station for cataract surgery. METHODS Case examples are presented along with information and relevant clinical data obtained from the OPD-Scan II aberrometer and OPD-Station software. All eyes underwent corneal topography, wavefront aberrometry, autorefraction, keratometry, and pupillometry measu...