Inner ear volumetric measurements using high-resolution 3D T2-weighted fast spin-echo MR imaging: initial experience in healthy subjects.

نویسندگان

  • E R Melhem
  • H Shakir
  • S Bakthavachalam
  • C B MacDonald
  • J Gira
  • S D Caruthers
  • H Jara
چکیده

BACKGROUND AND PURPOSE Adult size is achieved in the inner ear labyrinth by approximately 25 weeks' gestation, and minimal variability in age, sex, side, and race is found after birth. In this study, we opted to determine the reproducibility of inner ear volumetric measurements generated from high-resolution heavily T2-weighted 3D fast spin-echo MR images. METHODS The temporal bones of 23 volunteers were imaged using a heavily T2-weighted 3D fast spin-echo MR imaging technique. The images were assessed by a neuroradiologist for the presence of inner ear configurational anomalies and, most important, for complete coverage of the inner ear labyrinth. Subsequently, the volume of the fluid in the inner ear was determined by two observers using a semiautomated segmentation algorithm. The mean, SD, range, and coefficient of variation of fluid volume in the inner ear were calculated. Age-, sex-, and side-related differences in the inner ear volumetric measurements were evaluated using analysis of variance. Interrater consistency in the inner ear volumetric measurements was evaluated by comparing the calculated coefficients of reliability. RESULTS Volumetric measurements were available from 46 inner ears in 23 volunteers. The mean volume was 227.8 mm3 (SD, 24.4 mm3), and the coefficient of variation was 10.7%. No age-, sex-, or side-related differences in the inner ear volumetric measurements were found (F ratios were 4.33, 5.04, and 0.26, respectively). Interrater consistency, as assessed by the coefficient of reliability, was 5.3%. CONCLUSION Reproducible volumetric measurements of the inner ear labyrinth can be obtained by applying a semiautomated segmentation algorithm to a heavily T2-weighted 3D fast spin-echo MR imaging data set. These volumetric measurements may help identify patients with congenital sensorineural hearing loss and normal inner ear configuration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast recovery 3D fast spin-echo MR imaging of the inner ear at 3 T.

High-resolution MR imaging of the inner ear with a heavily T2-weighted 3D fast spin-echo sequence has been performed successfully at 1.5 T. However, at 3 T, the longer T1 time of CSF necessitates a longer TR, resulting in significantly prolonged imaging times. In this study, the fast recovery 3D fast spin-echo sequence, which permits the TR to be reduced while maintaining T2 contrast, was optim...

متن کامل

Detection of focal hepatic lesions with MR imaging: prospective comparison of T2-weighted fast spin-echo with and without fat suppression, T2-weighted breath-hold fast spin-echo, and gadolinium chelate-enhanced 3D gradient-recalled imaging.

OBJECTIVE The purpose of this study was to compare breath-hold three-dimensional (3D) rapid gradient-echo (GRE) MR imaging obtained before and after gadolinium chelate injection with T2-weighted fast spin-echo and T2-weighted breath-hold fast spin-echo (BHFSE) MR imaging in the detection of focal hepatic masses. SUBJECTS AND METHODS Fifty-three patients with 108 focal hepatic masses had, pros...

متن کامل

CT and MR imaging characteristics of intravestibular lipoma.

BACKGROUND AND PURPOSE Intracranial lipomas are uncommon congenital malformations that most often are asymptomatic. A rare subset of intracranial lipomas arises within the vestibule of the inner ear, which can cause sensorineural hearing loss. We present the CT and MR imaging characteristics of lipomas within the vestibule of the inner ear and propose a pathogenetic mechanism for this malformat...

متن کامل

High Resolution Inner Ear Imaging with a Fast Recovery 3D Fast Spin Echo Sequence (FR-3DFSE)

Introduction: FSE based techniques are being considered for the screening of inner ear tumors instead’ of the more expensive contrast enhanced Tl weighted gradient echo imaging techniques [l-3]. This consideration is due to the insensitivity of FSE to magnetic inhomogeneities known to exist around the inner ear [4] as well as the excellent T2 weighting possible for the fluid filled inner ear st...

متن کامل

High prevalence of pineal cysts in healthy adults demonstrated by high-resolution, noncontrast brain MR imaging.

BACKGROUND AND PURPOSE Although the prevalence of pineal cysts in autopsy series has been reported as being between 25% and 40%, MR studies have documented their frequency to range between 1.5% and 10.8%. The purpose of this high-resolution brain MR imaging study at 1.9T was to determine the prevalence of pineal cysts in healthy adults. MATERIALS AND METHODS Brain MR images of 100 healthy you...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 19 10  شماره 

صفحات  -

تاریخ انتشار 1998