Limits on the Accuracy of Drift Chambers and Calibration Beams
نویسنده
چکیده
years from now. The understanding of intrinsic limits on the spatial accuracy of drift chambers, and the development of new methods for calibrating them, are therefore still relevant. The present talk attempts to review the state of the art. In order to see what are the main questions to be asked, I have summarized in Table 1 the main characteristics of the drift-chamber detectors proposed for LEP. These detectors fall into two classes: i)
منابع مشابه
Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties
Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...
متن کاملCalibration of iridium-192 source by ionization chamber for high dose rate brachytherapy
Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...
متن کاملStability Study of Ionization Chambers in Standard Mammography Radiation Beams
The ionization chambers are widely utilized in diagnostic radiology quality control and dosimetry. They are simple to use, and can be found commercially in various types depending on their applications. They are the recommended devices for the determination of the beam qualities in mammographic range. To assure the reliability of the measurements, the stability of the response of the ionization...
متن کاملA Comparison of dosimetric parameters between IAEA TRS-398, AAPM TG-51 protocols and Monte-Carlo simulation
Background: Two protocols of AAPM TG-51 and IAEA TRS-398 were compared followed by a measurement and Monte Carlo simulation of beam quality correction factor, KQ, AAPM TG-51 and IAEA TRS-398 protocols were compared for the absorbed dose to water for DW, and KQ parameters. Materials and Methods: Dose measurements by either protocols were performed with cylindrical and plane parallel ch...
متن کاملEvaluating the effect of energy on calibration of thermo-luminescent dosimeters 7-LiF:Mg,Cu,P (GR-207A)
Background: 7-LiF: Mg,Cu,P (GR-207A) is one kind of thermo-luminescent dosimeters (TLD) which can be used in diagnostic radiology and radiotherapy applications. Because of having suitable properties such as good sensitivity, small size and being tissue equivalent, thermo-luminescent dosimetry has been one of the most important techniques in medicine over many years. Choosing a correct energy fo...