The aim of this study was to evaluate the preparation time and the amounts of apically extruded debris and irrigant using different nickel-titanium instrumentation systems. Forty-five extracted single-rooted mandibular premolar teeth were selected and divided into three groups. The root canals were instrumented according to the manufacturers' instructions, using a reciprocating single-file system, a single-file rotary system and a multiple-file rotary system. Bidistilled water was used as the irrigant solution. The apically extruded debris and irrigant were collected into preweighed Eppendorf tubes. The amounts of extruded debris and irrigant were assessed with a precision micro-balance. The Eppendorf tubes were incubated at 37°C for 15 days. After the incubation period, they were weighed again to assess the debris extrusion. The time required to prepare the canals was also recorded. The results were statistically analyzed using MANOVA and Bonferroni's adjustment. Considering the apically extruded debris and irrigant, there were no statistically significant differences among the groups (p > 0.05). The Reciproc group produced the highest debris (0.000632 ± 0.000162 gr) and irrigant (0.844587 ± 0.437814 ml) extrusion values. While the least extruded debris was observed with OneShape (0,000431 ± 0,000171 gr), the least extruded irrigant was observed with ProTaper system (0.564147 ± 0.370596 ml). Instrumentation was faster using the Reciproc than the other two instruments (70.27 ± 13.38 s) (p < 0.05). All of the instrumentation systems used in this study produced apical debris and irrigant extrusion. The reciprocating single-file system tended to produce more debris and irrigant extrusion, compared with the rotary systems. Considering the preparation time, the single-file systems appeared to be advantageous due to their working time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Apically Extruded Debris and Irrigant Produced by Different Nickel-Titanium Instrument Systems in Primary Teeth.

AIM The purpose of this study was to determine the amount of extruded debris and irrigant associated with different single-file systems and one multiple-file system. MATERIALS AND METHODS Forty-five newly extracted single rooted primary canine teeth were used in this study. The root canals were instrumented using the reciprocating single-file system, the single-file rotary system and the mult...

متن کامل

Evaluation of Apical Extrusion of Debris and Irrigant Using Two New Reciprocating and One Continuous Rotation Single File Systems

OBJECTIVE Apical extrusion of debris and irrigants during cleaning and shaping of the root canal is one of the main causes of periapical inflammation and postoperative flare-ups. The purpose of this study was to quantitatively measure the amount of debris and irrigants extruded apically in single rooted canals using two reciprocating and one rotary single file nickel-titanium instrumentation sy...

متن کامل

Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems.

INTRODUCTION The purpose of this in vitro study was to assess the amount of apically extruded debris using rotary and reciprocating nickel-titanium instrumentation systems. METHODS Eighty human mandibular central incisors were randomly assigned to 4 groups (n = 20 teeth per group). The root canals were instrumented according to the manufacturers' instructions using the 2 reciprocating single-...

متن کامل

Assessment of apically extruded debris produced by the single-file ProTaper F2 technique under reciprocating movement.

OBJECTIVE This study was designed to quantitatively evaluate the amount of dentin debris extruded from the apical foramen by comparing the conventional sequence of the ProTaper Universal nickel-titanium (NiTi) files with the single-file ProTaper F2 technique. STUDY DESIGN Thirty mesial roots of lower molars were selected, and the use of different instrumentation techniques resulted in 3 group...

متن کامل

Comparison of apically extruded debris and instrumentation time using rotary, endodontic handpiece and hand files in primary molar teeth: (In-vitro )

Abstract Background & Aim : This study was aimed to compare the instrumentation time and the amount of debris extruded apically  during root canal preparation using hand files ,Mtwo rotary system and endodontic handpiece  in primary molar teeth. Method & Material : In this experimental study, sixty roots of  primary molars of human teeth were assigned to three groups (for each group, n=20). The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian oral research

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2015