Ciliary sulcus microcysts as the source of a white-to-white sizing mismatch with the implantable Collamer lens.
نویسندگان
چکیده
The Visian Implantable Collamer Lens ([ICL] STAAR Surgical, Monrovia, CA) is a ciliary sulcusplaced posterior chamber intraocular lens used in the management of high myopia in phakic patients.1 Because of the risk of cataract, ICL vaulting greater than 250 μm is recommend to reduce rubbing of the ICL on the crystalline lens. However, excessive vaulting greater than 750 μm increases the risk of angle closure and pupillary block glaucoma.2 Based on U.S. Food and Drug Administration (FDA) studies, the recommended method for predicting the appropriate lens length and potential vault height is the white-to-white horizontal corneal diameter, which is best measured during biometric measurements. Alternatively, one could also directly measure the ciliary sulcus diameter with ultrasound biomicroscopy (UBM).3 Although white-towhite is the FDA-approved measurement, evidence suggests that it does not reliably correlate with the ciliary sulcus diameter. Consequently, sulcus-based diameter measurements with UBM sizing are superior in predicting the proper postoperative ICL vaulting.2,3 Whenever there is a poor correlation between white-to-white and sulcus-to-sulcus measurements, concern should be raised for an underlying mass lesion or measurement error. To illustrate this point, a 42-year-old woman diagnosed as having high myopia, white-to-white measurements of 12.2 mm, and sulcusto-sulcus measurements of 10.39 mm in the right eye underwent ICL implantation of a 12.6-mm lens after failed insertion of a 13.2-mm lens. Persistent high vaulting of the ICL (1.53 to 23 corneal thickness) developed immediately postoperatively with narrowed but open angles. UBM showed multiple small (50 to 350 μm) cysts throughout the ciliary sulcus in all meridians (Figure 1). These microcysts were not detected prior to implantation, but only after imaging the sulcus in both longitudinal and lateral orientations at all clock meridians with a 50-MHz UBM (Quantel, Bozeman, MT). Because of the persistent ICL vaulting and angle narrowing, the ICL was explanted with no further surgical intervention planned. Ciliary body cysts are a common and benign finding in UBM. Kunimatsu et al. found that 54.3% of normal patients had detectable cysts.4 They are usually congenital neuroepithelial lesions located at the iridociliary junction or the pars plicata.5 These cysts are almost impossible to detect with slit-lamp examination or gonioscopy, but can be more easily visualized with the UBM.6 There are a few features that make this case unique. First, due to their size, the microcysts were only found after the ICL implantation, and only after careful segmental evaluation with the UBM. Second, our case did not involve one single cyst in the ciliary body, but multiple microcysts in all quadrants of the ciliary sulcus. Previous research by Wang and Yao found that multiple cysts and multiple quadrant cysts have a significant effect on angle narrowing compared to a single cyst in phakic eyes.6 Therefore, despite the patient’s good visual acuity and normal intraocular pressure, explantation was performed. Third, the white-to-white and sulcus-to-sulcus measurements had considerable discrepancy (12.2 and 10.39 mm, respectively, in the right eye), and should have been a warning sign for the use of the white-to-white measurements in sizing the ICL in this patient. We believe the larger discrepancy in our patient was a feature of multiple cysts in all meridians. There are two important points to be noted in regard to this case. First, using the FDA-approved and recommended white-to-white measurements in the ICL sizing of our patient led to a false overestimation of the required lens size. Second, ciliary sulcus Figure 1. Transverse ultrasound biomicroscopy showing one of the cysts measuring 350 μm at the 9-o’clock position (A) Multiple microcysts less than 100 μm at the 3-o’clock position. (B) The microcysts create a white-to-white and sulcus-to-sulcus mismatch in implantable collamer lens sizing. A
منابع مشابه
Correlation between Preoperative Sizing of Implantable Collamer Lens (ICL) by White-to-white and Sulcus-to-sulcus Techniques, and Postoperative Vault Size Measured by Sheimpflug Imaging
Purpose: To evaluate correlations between preoperative sizing of Implantable Collamer Lens (ICL) by white-towhite and sulcus-to-sulcus techniques, and postoperative vault size measured by Sheimpflug imaging. Setting: Persian Eye Clinic, a private eye clinic located in Isfahan city, Iran Design: Prospective, nonrandomized clinical trial Methods: This prospective clinical trial included 63 eyes o...
متن کاملMeasurement of the crystalline lens radius with artemis very high frequency ultrasound biomicroscopy for implantable collamer lens sizing.
To the Editor: In their recent article, Reinstein et al.1 described the use of the Artemis 2 very high frequency digital ultrasound (ArcScan, Inc., Morrison, CO) to calculate the fit of the Visian Implantable Collamer Lens (ICL). Another parameter previously proposed as influencing ICL vaulting is the crystalline lens anterior radius of curvature (ALR).2 The ALR has not yet been used in any pre...
متن کاملBuffering zone of implantable Collamer lens sizing in V4c
BACKGROUND The purpose of this study was to identify factors related to the unexpected vault in V4c implantable collamer lens (ICL; STAAR Surgical) implantation. METHODS V4c ICLs were implanted in 43 eyes of 43 patients for the correction of myopia. The implanted V4c ICL sizes were determined individually with our previous V4 ICL sizing nomogram based on the sulcus-to-sulcus diameter (STS), a...
متن کاملMeta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lens
The purpose of this review is to summarize relevant data from publications appearing in the peer-reviewed scientific literature over the past decade since US Food and Drug Administration approval of the implantable collamer lens (ICL), and, in particular, to review studies relating to sizing methodology, safety, and effectiveness, as well as more recent studies reporting clinical outcomes of th...
متن کاملAuthor’s response to reviews Title: Buffering Zone of Implantable Collamer Lens Sizing in V4c Authors:
Title: Buffering Zone of Implantable Collamer Lens Sizing in V4c Authors: Seung Wan Nam ([email protected]) Dong Hui Lim ([email protected]) Joo Hyun ([email protected]) Eui-Sang Chung ([email protected]) Tae-Young Chung ([email protected]) Version: 1 Date: 04 Sep 2017 Author’s response to reviews: Alja Crnej (Reviewer 1): 1. Page 8, line 130 how did you decide what was too large what w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 31 3 شماره
صفحات -
تاریخ انتشار 2015