Remedying and preventing endodontic rotary nickel-titanium (NiTi) file breakage.

نویسنده

  • James K Bahcall
چکیده

Of all the procedural problems that can occur when practicing dentistry, endodontic file breakage is one dilemma that not only can lead to extreme stress for the clinician, but can cause great anxiety for the patient as well. Separated rotary nickel-titanium (NiTi) files can also pose an increased risk of post-endodontic complications. Understanding why and how endodontic file breakage occurs, including the two main factors that contribute to this type of incident, can help clinicians employ prevention strategies and overcome this predicament if it does occur. The purpose of this article is to discuss the causes of separated endodontic rotary NiTi files, explain how to prevent this problem from happening, describe the removal of a broken file, and discuss the prognosis for instances where the separated file cannot be removed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Current Strategies in Metallurgical Advances of Rotary NiTi Instruments: A Review

NiTi alloy has been used as the raw material for making endodontic files. The interest in NiTi instrument research has not waned with time. In fact, there is a renewed interest in this field, notably through the application of modern research tools and techniques from other fields, making it a truly cross-disciplinary area of research. In 1988, Walia and colleagues introduced nickeltitanium (Ni...

متن کامل

Current Strategies in Metallurgical Advances of Rotary NiTi Instruments: A Review

NiTi alloy has been used as the raw material for making endodontic files. The interest in NiTi instrument research has not waned with time. In fact, there is a renewed interest in this field, notably through the application of modern research tools and techniques from other fields, making it a truly cross-disciplinary area of research. In 1988, Walia and colleagues introduced nickeltitanium (Ni...

متن کامل

Current Strategies in Metallurgical Advances of Rotary NiTi Instruments: A Review

NiTi alloy has been used as the raw material for making endodontic files. The interest in NiTi instrument research has not waned with time. In fact, there is a renewed interest in this field, notably through the application of modern research tools and techniques from other fields, making it a truly cross-disciplinary area of research. In 1988, Walia and colleagues introduced nickeltitanium (Ni...

متن کامل

The accuracy of the Raypex5 electronic apex locator using stainless-steel hand K-file versus nickel-titanium rotary Mtwo file.

OBJECTIVES Today many clinicians use both stainless-steel hand K-files and nickel- titanium rotary files during endodontic treatment. It is of great importance for the clinician to have confidence in the accuracy of an apex locator even if these files were used interchangeably. The purpose of this in vitro study was to evaluate the accuracy of the Raypex5 electronic apex locator using stainless...

متن کامل

Endodontic rotary nickel-titanium instrument systems.PDF

Since the end of the nineteenth century, automated root canal instrumentation has been available, but systems had many problems. The challenges of increased canal blockage, instrument breakage, and insufficient canal debridement were related to the use of stainless steel instruments and have been dramatically improved with the introduction of nickel-titanium (NiTi) files. The first useable NiTi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Compendium of continuing education in dentistry

دوره 34 5  شماره 

صفحات  -

تاریخ انتشار 2013