FRET spectral unmixing: a ratiometric fluorescent nanoprobe for hypochlorite.
نویسندگان
چکیده
A specific ratiometric nanoprobe for hypochlorite was constructed as a paradigm of FRET spectral unmixing. The separation of FRET pairs' emissions reaches 175 nm, which ensures that the FRET probing is more accurate. This new nanoprobe shows high selectivity and potential in biological systems.
منابع مشابه
Multifunctional self-assembled polymeric nanoprobes for FRET-based ratiometric detection of mitochondrial H2O2 in living cells.
A ratiometric, multifunctional nanoprobe was prepared consisting of a self-assembled polymeric micelle as the carrier, tetraphenylethene (TPE) as the donor, fluorescent boronate as the H2O2-responsive acceptor, and triphenylphosphonium as a mitochondria-targeted moiety. The assembled nanoparticles could detect both exogenous and endogenous mitochondrial H2O2 changes in living cells.
متن کاملSpectral Unmixing: Analysis of Performance in the Olfactory Bulb In Vivo
BACKGROUND The generation of transgenic mice expressing combinations of fluorescent proteins has greatly aided the reporting of activity and identification of specific neuronal populations. Methods capable of separating multiple overlapping fluorescence emission spectra, deep in the living brain, with high sensitivity and temporal resolution are therefore required. Here, we investigate to what ...
متن کاملA ratiometric fluorescent nanoprobe based on terbium functionalized carbon dots for highly sensitive detection of an anthrax biomarker.
A ratiometric fluorescent nanoprobe based on terbium functionalized carbon dots (CDs) was designed to detect dipicolinic acid (DPA) as an anthrax biomarker with high selectivity and sensitivity. CDs were generated by one-step synthesis using an ethylenediaminetetraacetic acid precursor, and served as a scaffold for coordination with Tb(3+) and a fluorescence reference.
متن کاملReal-time detection of hypochlorite in tap water and biological samples by a colorimetric, ratiometric and near-infrared fluorescent turn-on probe.
In this paper, we report a highly selective and sensitive ratiometric NIR fluorescent probe that can be used for real-time detection of the biologically important hypochlorite with colorimetric and significant NIR fluorescent turn-on signal changes at NIR excitation wavelength. In addition, experiments showed that this probe can be applied to detect hypochlorite in tap water, serum samples, and...
متن کاملA ratiometric fluorescent probe for in situ quantification of basal mitochondrial hypochlorite in cancer cells.
A ratiometric fluorescent probe () for ClO(-) based on the conjugate of coumarin-rhodamine was presented, which could sense ClO(-) with fast response (within 5 s), high sensitivity and excellent selectivity. More importantly, is the first mitochondria-targeted ratiometric fluorescent probe to image exogenous and endogenous ClO(-).
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chemical communications
دوره 48 24 شماره
صفحات -
تاریخ انتشار 2012