Computational fluid dynamics (CFD) assisted performance evaluation of the Twincer™ disposable high-dose dry powder inhaler.
نویسندگان
چکیده
OBJECTIVES To use computational fluid dynamics (CFD) for evaluating and understanding the performance of the high-dose disposable Twincer™ dry powder inhaler, as well as to learn the effect of design modifications on dose entrainment, powder dispersion and retention behaviour. METHODS Comparison of predicted flow and particle behaviour from CFD computations with experimental data obtained with cascade impactor and laser diffraction analysis. KEY FINDINGS Inhaler resistance, flow split, particle trajectories and particle residence times can well be predicted with CFD for a multiple classifier based inhaler like the Twincer™. CFD computations showed that the flow split of the Twincer™ is independent of the pressure drop across the inhaler and that the total flow rate can be decreased without affecting the dispersion efficacy or retention behaviour. They also showed that classifier symmetry can be improved by reducing the resistance of one of the classifier bypass channels, which for the current concept does not contribute to the swirl in the classifier chamber. CONCLUSIONS CFD is a highly valuable tool for development and optimisation of dry powder inhalers. CFD can assist adapting the inhaler design to specific physico-chemical properties of the drug formulation with respect to dispersion and retention behaviour.
منابع مشابه
The use of computational fluid dynamics in inhaler design.
INTRODUCTION Computational fluid dynamics (CFD) has recently seen increased use in the design of pharmaceutical inhalers. The use of CFD in the design of inhalers is made difficult by the complex nature of aerosol generation. At present, CFD has provided valuable insight into certain aspects of inhaler performance, though limitations in computational power have prevented the full implementation...
متن کاملEffect of design on the performance of a dry powder inhaler using computational fluid dynamics. Part 1: Grid structure and mouthpiece length.
This study investigates (1) the effect of modifying the design of a dry powder inhaler on the device performance, and (2) which design features significantly contribute to overall inhaler performance. Computational Fluid Dynamics (CFD) analysis was performed to determine how the flowfield generated in an Aerolizer at 60 l min(-1) varied when the inhaler grid and mouthpiece were modified. The co...
متن کامل0710_GF_ONdrugDelivery Pulmonary April 2012.indd
After the Montreal Protocol banned the use of chlorofluorocarbon (CFC) propellants in metereddose inhalers (MDIs), the pharmaceutical industry now has provided suitable alternatives, one of which is the dry-powder inhaler (DPI). A DPI is a device in which small doses of drug powder are delivered to the lung. The inhaled dose consists of drug particles attached to carrier particles. The drug par...
متن کاملEffect of design on the performance of a dry powder inhaler using computational fluid dynamics. Part 2: Air inlet size.
This study investigates the effect of air inlet size on (i) the flowfield generated in a dry powder inhaler, and (ii) the device-specific resistance, and the subsequent effect on powder deagglomeration. Computational fluid dynamics (CFD) analysis was used to simulate the flowfield generated in an Aerolizer with different air inlet sizes at 30, 45, and 60 l/min. Dispersion performance of the mod...
متن کاملDry powder inhaler device influence on carrier particle performance.
Dry powder inhalers (DPIs) are distinguished from one another by their unique device geometries, reflecting their distinct drug detachment mechanisms, which can be broadly classified into either aerodynamic or mechanical-based detachment forces. Accordingly, powder particles experience different aerodynamic and mechanical forces depending on the inhaler. However, the influence of carrier partic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of pharmacy and pharmacology
دوره 64 9 شماره
صفحات -
تاریخ انتشار 2012