Magnetic retention and bar-clip attachment for implant-retained auricular prostheses: a comparative analysis.

نویسندگان

  • Andréa Alves de Sousa
  • Beatriz Silva Câmara Mattos
چکیده

Retention systems for implant-retained auricular prostheses using either bar-clip attachments with 2 or 3 clips or retention with 2 or 3 magnets were wear tested (insertion and removal cycles) to simulate clinical periods of use. Measurements were taken at intervals of 540 cycles, which represents a period of use of approximately 6 months, for up to 3,240 cycles. Assessments of retentive force were carried out before, during, and after the wear test. Statistical analysis indicated that the bar-clip systems provided higher retention than the magnetic systems. The bar-clip attachment with 2 clips showed a significant loss of retentive force after wear testing (P < .05), suggesting lower durability and shorter clinical life. The retention provided by the bar-clip attachment with 3 clips remained stronger than that provided by all other systems tested. At the end of the wear test, the magnetic systems showed very little loss of retention but were still less retentive than the bar-clip systems, suggesting higher durability under clinical simulation despite the lower retention initially provided.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication of an Implant-Supported Orbital Prosthesis with Bar-Magnetic Attachment: A Clinical Report

Implant-supported craniofacial prostheses are made to restore defective areas in the face and cranium. This clinical report describes a technique for fabrication of an orbital prosthesis with three adjacent implants in the left lateral orbital rim of a 60-year-old woman. Selection of appropriate attachment system (individual magnetic abutments versus bar-clip attachment) for implant-supported o...

متن کامل

An in vitro comparative study to evaluate the retention of different attachment systems used in implant-retained overdentures

AIM The aim of this in vitro study was to compare the change in the retentive force and removal torque of three attachment systems during simulation of insertion-removal cycles. METHODOLOGY Edentulous mandibular models were made with heat-cured polymethyl methacrylate resin. Two implant replicas (CMI), of 3.75 mm diameter and 10 mm length, were placed in the intraforaminal region. Acrylic res...

متن کامل

Magnet-retained auricular prosthesis with an implant-supported composite bar: a clinical report.

The use of craniofacial implants to assist in retaining auricular prostheses often requires complex laboratory procedures, involving production of an accurate casting, fitting of a precious alloy bar, and the use of clips. A simplified method for the retention of an auricular prosthesis with a composite bar and magnets is described in this article.

متن کامل

Implant-Retained Auricular Prosthesis: A Case Report

Extraoral implant retained prosthesis have been proven to be a predictable treatment option for maxillofacial rehabilitation. This case report describes the clinical and laboratory procedures for fabricating an auricular prosthesis.In this case report, an auricular prosthesis was fabricated for a patient who lost the left and right external ear in an electrical burn. Extraoral implants and bar-...

متن کامل

Stress analysis in oral obturator prostheses over parallel and tilted implants: photoelastic imaging.

This study aimed to evaluate the stress distribution through the photoelastic method in implant-retained palatal obturators prostheses. Two photoelastic models with bucco-sinusal communication were fabricated, one model without implants and another with two parallel implants and one tilted in the molar region. A conventional obturator prosthesis and five implant-retained obturators dentures wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The International journal of prosthodontics

دوره 21 3  شماره 

صفحات  -

تاریخ انتشار 2008