An in vivo evaluation of the mycobacterial filtration efficacy of three breathing filters used in anesthesia.

نویسندگان

  • Daniel P Vezina
  • Claude A Trépanier
  • Martin R Lessard
  • Marie Gourdeau
  • Claude Tremblay
  • Robert Guidoin
چکیده

BACKGROUND The use of breathing filters (BFs) has been recommended to protect the anesthesia apparatus in proven or suspected cases of tuberculosis. Some investigators have also suggested the use of BF to alleviate the need to change anesthesia breathing circuits after each case. This study evaluated the filtration efficacy of three different BFs to prevent mycobacterial contamination of breathing circuits in a model that uses a test animal. METHODS Ten Pall BB25A (pleated hydrophobic) (Pall Canada Ltd., Mississauga, Ontario, Canada), six DAR Barrierbac S (felted electrostatic; Mallinckrodt DAR, Mirandola, Italy), and six Baxter Airlife (felted electrostatic; Baxter Canada, Mississauga, Ontario, Canada) BFs were studied. For each BF tested, 20 ml of a high concentration suspension of Mycobacterium chelonae (range, 2.0 x 10 to 9.0 x 10 colony-forming units/ml) was nebulized during 2 h at the proximal end of the endotracheal tube of anesthetized pigs. At the end of the nebulization period, the BFs were sampled for culture. The titer reduction value (number of microorganisms challenging the BF divided by the number of microorganisms recovered downstream of the BF) and the removal efficiency (difference between the number of microorganisms challenging the BF and the number of microorganisms recovered downstream of the BF, divided by the number of microorganisms challenging the BF) were calculated. RESULTS The median titer reduction values were 5.6 x 10, 6.0 x 10, and 8.0 x 10 (P < 0.0005), and the median removal efficiencies were greater than 99.999%, greater than 99.999%, and 100% (P = not significant) for the DAR Barrierbac S, the Baxter Airlife, and the Pall BB25A, respectively. CONCLUSIONS Among the three BFs studied, only the Pall BB25A completely prevented the passage of M. chelonae, thus protecting the anesthesia breathing circuit from mycobacterial contamination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Simultaneous Effect of Melt Filtration and Cooling Rate on Tensile Properties of A356 Cast Alloy

The combined influence of both melt filtration and cooling rate on the microstructure features and mechanical properties of A356 cast alloy was studied. A step casting model with five different thicknesses was used to obtain different cooling rates. The effect of melt filtration was studied by using of 10 and 20 ppi ceramic foam filters in the runner. Results showed that secondary dendrite arm ...

متن کامل

Anesthesia and Sedation in Chough (Pyrrhocorax pyrrhocorax) Following Intranasal Administration of Diazepam, Midazolam, Xylazine with or without Ketamine: Clinical Evaluation

Objective- This study aimed to compare sedation efficacy in intranasal administration of xylazine, diazepam and midazolam with or without ketamine in Chough. Design- To determine the sedation efficacy, an experimental in vivo study was employed. Animals- Seven healthy Choughs were examined in the current study. Procedu...

متن کامل

Optimization of the electrospinning process of polyurethane nanofibers and their filtration performance for use in respiratory protection mask filters

Background and Aim: Electrospun nanofibers can be used to produce filter media in personal protective equipment for the military. The present study aimed to optimize the electrospinning process used to create polyurethane nanofiber substrates and compare the optimum substrate filtration performance with a typical commercial substrate used in the structure of N95 respirators. Methods: In this ex...

متن کامل

Panel Discussion: Filtration of breathing gases during mechanical ventilation

Filtration of contaminated breathing gases is a necessary measure in mechanical ventilation. There are two types of filters available for filtration of breathing gases: mechanical filters and electrostatic filters. Filter efficiency can be established through a number of means, the most stringent being the High Efficiency Particulate Air (HEPA) test. While a variety of HEPA-grade filters are av...

متن کامل

`Evaluation of the analgesic efficacy of melatonin in patients undergoing cesarean section under spinal anesthesia: A prospective randomized double-blind study

Melatonin has been suggested as a new natural pain killer in inflammatory pain and during surgical procedures. We designed this randomized double-blind controlled study to evaluate the analgesic efficacy and also optimal preemptive dose of melatonin in patients undergoing cesarean section under spinal anesthesia.One hundred twenty patients scheduled for cesarean section under spinal anesthesia ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 101 1  شماره 

صفحات  -

تاریخ انتشار 2004