Gas compression in lungs decreases peak expiratory flow depending on resistance of peak flowmeter.

نویسندگان

  • O F Pedersen
  • T F Pedersen
  • M R Miller
چکیده

It has recently been shown (O. F. Pedersen T. R. Rasmussen, O. Omland, T. Sigsgaard, P. H. Quanjer. and M. R. Miller. Eur. Respir. J. 9: 828-833, 1996) that the added resistance of a mini-Wright peak flowmeter decreases peak expiratory flow (PEF) by approximately 8% compared with PEF measured by a pneumotachograph. To explore the reason for this, 10 healthy men (mean age 43 yr, range 33-58 yr) were examined in a body plethysmograph with facilities to measure mouth flow vs. expired volume as well as the change in thoracic gas volume (Vb) and alveolar pressure (PA). The subjects performed forced vital capacity maneuvers through orifices of different sizes and also a mini-Wright peak flowmeter. PEF with the meter and other added resistances were achieved when flow reached the perimeter of the flow-Vb curves. The mini-Wright PEF meter decreased PEF from 11.4 +/- 1.5 to 10.3 +/- 1.4 (SD) l/s (P < 0.001), PA increased from 6.7 +/- 1.9 to 9.3 +/- 2.7 kPa (P < 0.001), an increase equal to the pressure drop across the meter, and caused Vb at PEF to decrease by 0.24 +/- 0.09 liter (P < 0.001). We conclude that PEF obtained with an added resistance like a mini-Wright PEF meter is a wave-speed-determined maximal flow, but the added resistance causes gas compression because of increased PA at PEF. Therefore, Vb at PEF and, accordingly, PEF decrease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peak flowmeter resistance decreases peak expiratory flow in subjects with COPD.

Previous studies have shown that the added resistance of a mini-Wright peak expiratory flow (PEF) meter reduced PEF by approximately 8% in normal subjects because of gas compression reducing thoracic gas volume at PEF and thus driving elastic recoil pressure. We undertook a body plethysmographic study in 15 patients with chronic obstructive pulmonary disease (COPD), age 65.9 +/- 6.3 yr (mean +/...

متن کامل

Peak Expiratory Flow Rate in Healthy Children from Tehran

Background: Measuring peak expiratory flow rate has been suggested as an important tool in asthma management by all international guidelines.  Objective: Studies on various populations have shown considerable variations in normal values of peak expiratory flow rate. Since reference standards for Iranian children are not available, the present study was performed to establish these standards. Me...

متن کامل

Novel method for measuring effects of gas compression on expiratory flow.

During forced vital capacity maneuvers in subjects with expiratory flow limitation, lung volume decreases during expiration both by air flowing out of the lung (i.e., exhaled volume) and by compression of gas within the thorax. As a result, a flow-volume loop generated by using exhaled volume is not representative of the actual flow-volume relationship. We present a novel method to take into ac...

متن کامل

Innovative Methodology Novel method for measuring effects of gas compression on expiratory flow

Sharafkhaneh, Amir, Todd M. Officer, Sheila GoodnightWhite, Joseph R. Rodarte, and Aladin M. Boriek. Novel method for measuring effects of gas compression on expiratory flow. Am J Physiol Regul Integr Comp Physiol 287: R479–R484, 2004. First published April 29, 2004; 10.1152/ajpregu.00573.2003.—During forced vital capacity maneuvers in subjects with expiratory flow limitation, lung volume decre...

متن کامل

Gas compression artefacts when testing peak expiratory flow meters with mechanically-driven syringes.

Mechanically-driven syringes used to test peak expiratory flow (PEF) meters must produce the American Thoracic Society (ATS) standard waveforms with PEF accuracy of 2%. However, gas compression within the syringe could result in significant PEF inaccuracy when testing high resistance meters. The gas compression artefact was investigated in a mechanical syringe (PWG; MH Custom Design & Mfg L.C.,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 83 5  شماره 

صفحات  -

تاریخ انتشار 1997