Body composition, hydration, and related parameters in hemodialysis versus peritoneal dialysis patients.

نویسندگان

  • Isabel Devolder
  • Annick Verleysen
  • Denise Vijt
  • Raymond Vanholder
  • Wim Van Biesen
چکیده

AIMS Maintaining euvolemia is an important goal in patients on renal replacement therapy. However, adequate assessment of volume status in clinical practice is hampered by a lack of accurate measuring tools. A new multifrequency bioimpedance tool has recently been validated. This study compares volume status in peritoneal dialysis (PD) and hemodialysis (HD) patients in a single center. METHODS Body Composition Monitoring (BCM; Fresenius Medical Care, Bad Homburg, Germany) was performed in all patients on PD or HD without contraindication. PD patients were measured with a full abdomen; HD patients were measured at the midweek session, once immediately before and once 20 minutes after dialysis. Clinical overhydration was defined as an overhydration-to-extracellular water ratio of >0.15. RESULTS Total body water, extracellular water, and intracellular water were 33.7 +/- 6.9 L versus 31.8 +/- 8.1 L vs 33.9 +/- 6.7 L, 16.4 +/- 3.9 L vs 15.3 +/- 4.9 L vs 16.8 +/- 3.3 L, and 17.1 +/- 6.2 L vs 16.5 +/- 4.6 L vs 17.2 +/- 3.9 L in the pre-HD, post-HD, and PD patients, respectively (p = NS). In the pre-HD and the PD patients, overhydration was 1.9 +/- 1.7 L and 2.1 +/- 2.3 L, whereas post-HD this was only 0.6 +/- 1.7 L (p < 0.001). Clinical overhydration was more prevalent in pre-HD and PD patients compared to post-HD patients (24.1% vs 22.3% vs 10%, p < 0.001). In multivariate models, overhydration was related to age, male gender, and post-HD status. CONCLUSION Although much clinical attention is paid to volume status, 24% of patients still have clinically relevant volume overload. Implementation of a reliable and clinically applicable tool to assess volume status is therefore necessary. It is possible to obtain comparable volume status in PD and HD patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spirometric Parameters: Hemodialysis Compared to Peritoneal Dialysis

Introduction: Renal failure affects the mechanical and the ventilatory function of the lungs. A few studies have evaluated the ventilatory and pulmonary function in dialysis patients. The present study aimed to compare Pulmonary Function Test (PFT) results in patients undergoing Hemodialysis (HD) and Peritoneal Dialysis (PD). Materials and Methods: We conducted a cross-sectional study on 50  pa...

متن کامل

Assessment of fluid status in peritoneal dialysis patients.

OBJECTIVES To assess the influence of abnormalities in fluid status and body composition on agreement between multifrequency bioimpedance analysis (MF-BIA), segmental BIA (sigmaBIA), the Watson formula, and tracer dilution techniques. DESIGN Cross-sectional. SETTING Multicenter. PATIENTS 40 patients (29 males, 11 females) on peritoneal dialysis (PD). MAIN OUTCOME MEASURES Agreement betw...

متن کامل

The Comparative Survey of Life Quality in Renal Transplant Recipients, Peritoneal Dialysis, and Hemodialysis Patients in Kerman in the Year 2013

Background & Objective: According to the World Health Organization (WHO) definition, quality of life is a state of complete physical, mental, and social health not merely the absence of the disease. End stage renal disease and its treatment affect patients' quality of life. Therefore, the present study surveyed the quality of life in renal transplant recipients, hemodialysis, and peritoneal di...

متن کامل

Application of bioelectrical impedance to clinical assessment of body composition in peritoneal dialysis.

Patients on peritoneal dialysis (PD) develop complex changes in body composition. These changes reflect hydration, nutrition, and body fat, all important elements reflecting patient well-being and efficacy of therapy that should be assessed and monitored as guides to patient management. They are all notoriously difficult to accurately measure in clinical practice and simultaneous abnormalities ...

متن کامل

Comparison of Marital Satisfaction in Hemodialysis and Peritoneal Dialysis Patients

Alternative kidney treatments, including renal transplantation, hemodialysis (HD), and peritoneal dialysis (PD), are administered when severe kidney failure occurs and the kidney can no longer function. The present study compares different dimensions of marital satisfaction in HD and PD patients so as to assist physicians and patients in choosing their appropriate treatment. This cross-se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Peritoneal dialysis international : journal of the International Society for Peritoneal Dialysis

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 2010