OBJECTIVE To assess the reliability of high-resolution computed tomographic scan (HRCT scan) for the diagnosis of otosclerosis and to determine its usefulness to predict hearing deterioration and surgical difficulties. STUDY DESIGN Prospective study. SETTING Tertiary reference center. PATIENTS Two hundred nine ears (200 patients) presenting progressive conductive hearing loss with normal tympanic membrane, abnormal stapedial reflex, and scheduled for stapes surgery. The mean age was 47.3 years. INTERVENTION All patients underwent HRCT scan before surgery (slice thickness of 0.6 to 1 mm). Stapedotomy was performed in 99% of cases. MAIN OUTCOME MEASURES High-resolution computed tomographic scan results were categorized as positive, doubtful, or negative. We classified a CT scan as positive for otosclerosis when a hypodense focus was seen around the otic capsule. Preoperative and postoperative air- and bone-conduction thresholds were collected. RESULTS Of 209 HRCT scans, 84.2% were classified positive, 8.6% doubtful, and 7.2% negative. In all patients with positive CT scan, otosclerosis was confirmed in surgery. Among 15 negative cases, we found 4 minor malformations and 1 fracture of the stapes. Footplate incidents (mobilized, floating, or fractured footplate; 5.3%) occurred significantly more frequently when an HRCT scan was negative or doubtful (p = 0.05). Mean preoperative air-bone gap was 27.7 dB (standard deviation, 10). Mean postoperative air-bone gap was within 10 dB in 65% and within 20 dB in 92% of cases. Greater than 10 dB deterioration of bone-conduction thresholds occurred in 2% of cases. Mean preoperative and postoperative bone-conduction thresholds were significantly lower in cases of round window obliteration, pericochlear, or internal auditory canal hypodensities (p < 0.005 and p < 0.0001, respectively). CONCLUSION In our series, the sensitivity of HRCT scan to otosclerosis was 95.1%. Hypodense otosclerotic foci were mostly localized at the anterior part of footplate. Negative or doubtful cases were associated with the highest incidence of stapes footplate complications. Foci involving otic capsule, internal auditory canal, or round window led to a significantly higher risk of sensorineural hearing loss.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acta Medica 4/12 2802.indd

Unilateral otosclerosis combined with avascular necrosis of stapes crura is a rare entity. it should be considered in a case of high grade otosclerosis. Symptoms are the same as in patients who suffer from common otosclerosis. Patients complain on progressive hearing loss and tinnitus. The diagnosis is made clinically by conventional audiologic evaluation and radiologically by x-ray mastoid Sch...

متن کامل

The Role of CT Scan in the Diagnosis of Otosclerosis

Objective: Otosclerosis has long been a clinical, audiological and tympanometric diagnosis. The definitive role and value of imaging is yet unclear in the clinical practice. In this work we aimed to study the temporal bone density using CT scan in patients clinically diagnosed as otosclerosis, not only to ascertain the value of CT scan, but also to study the correlation between the bone density...

متن کامل

Comparison of Preoperative Temporal Bone CT with Intraoperative Findings in Patients with Cholesteatoma

Introduction: Cholesteatoma is traditionally diagnosed by otoscopic examination and treated by surgery. The necessity for imaging in an uncomplicated case is controversial. This study was planned to investigate the usefulness of a preoperative high-resolution computed tomography (HRCT) scan in depicting the status of middle ear structures in the presence of cholesteatoma and also to compare the...

متن کامل

Design and Fabrication Process of MTF Phantom CT Scan

Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...

متن کامل

Comparing the Diagnostic Power of Chest CT Scan and RT-PCR in Diagnosis of COVID-19

Background and purpose: Proper diagnosis of patients with COVID-19 is one of the challenges in medical centers. RT-PCR is the standard and reference test in diagnosis of patients with COVID-19. This study aimed at accelerating the correct diagnosis of COVID-19 and the diagnostic power of chest CT scan and RT-PCR. Materials and methods: This study was performed in 569 patients with COVID-19 adm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology

دوره 30 8  شماره 

صفحات  -

تاریخ انتشار 2009