Data on diagnostic performance of stress perfusion cardiac magnetic resonance for coronary artery disease detection at the vessel level
نویسندگان
چکیده
Stress perfusion cardiac magnetic resonance (CMR) has been proposed as an important gatekeeper for invasive coronary angiography (ICA) and percutaneous coronary interventions (PCI) in patients evaluated for possible coronary artery disease (CAD) (Fihn et al., 2012; Montalescot et al., 2013) [1], [2]. Several meta-analyses have evaluated the accuracy of stress perfusion CMR to diagnose CAD at the vessel level (Danad et al., 2017; Dai et al., 2016; Jiang et al., 2016; Takx et al., 2015; Li et al., 2015; Desai and Jha, 2013; Jaarsma et al. 2012; Hamon et al., 2010; Nandalur et al. 2007) [3], [4], [5], [6], [7], [8], [9], [10], [11]. However, they included in the same analysis studies with different definitions of significant CAD (i.e. fractional flow reserve [FFR] < 0.75 and < 0.80 or coronary stenosis ≥ 50% and ≥ 70%), magnetic field strength (1.5 or 3 Tesla [T]), and study protocol (integration or not of late gadolinium enhancement [LGE] into stress perfusion protocol). Data of 34 studies (6091 arteries) have been pooled with the aim of analyzing the accuracy of stress perfusion CMR for the diagnosis of ischemic heart disease at the vessel level according to different definitions of significant CAD, magnetic field strength and study protocol (Arnold et al., 2010; Bettencourt et al., 2013; Cheng et al., 2007; Chiribiri et al., 2013; Cury et al., 2006; De Mello et al., 2012; Donati et al., 2010; Ebersberger et al., 2013; Gebker et al., 2008; Greulich et al., 2015; Hussain et al., 2016; Ishida et al., 2005, 2003; Kamiya et al., 2014; Kitagawa et al., 2008; Klein et al., 2008; Klem et al., 2006; Klumpp et al., 2010; Krittayaphong et al., 2009; Lockie et al., 2011; Ma et al., 2012; Merkle et al., 2007; Meyer et al., 2008; Mor-Avi et al., 2008; Pan et al., 2015; Papanastasiou et al., 2016; Pons Lladó et al., 2004; Sakuma et al., 2005; Salerno et al., 2014; Scheffel et al., 2010; van Werkhoven et al., 2010; Walcher et al., 2013; Watkins et al., 2009; Yun et al., 2015) [12-45]. This article describes data related article titled "Diagnostic Performance of Stress Perfusion Cardiac Magnetic Resonance for the Detection of Coronary Artery Disease" (Kiaos et al., submitted for publication) [46].
منابع مشابه
Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]
Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...
متن کاملRelationship between Late Gadolinium Enhancement Extent in Cardiac Magnetic Resonance Imaging and Severity of Coronary Artery Disease in Old Myocardial Infarction
Purpose: To assess the relationship between the severity of coronary arteries involvement and the extent and pattern of myocardial scars in Cardiac Magnetic Resonance of patients with history of remote myocardial infarction. Materials and Methods: The Cardiac Magnetic Resonance images of sixty patients with history of remote ST segment or non-ST segment elevation myocardial infarction were ...
متن کاملDiagnostic performance of stress cardiac magnetic resonance imaging in the detection of coronary artery disease: a meta-analysis.
OBJECTIVES The purpose of our study was to conduct an evidence-based evaluation of stress cardiac magnetic resonance imaging (MRI) in the diagnosis of coronary artery disease (CAD). BACKGROUND Stress cardiac MRI has recently emerged as a noninvasive method in the detection of CAD, with 2 main techniques in use: 1) perfusion imaging; and 2) stress-induced wall motion abnormalities imaging. M...
متن کاملHigh spatial resolution myocardial perfusion cardiac magnetic resonance for the detection of coronary artery disease
AIMS To evaluate the feasibility and diagnostic performance of high spatial resolution myocardial perfusion cardiac magnetic resonance (perfusion-CMR). METHODS AND RESULTS Fifty-four patients underwent adenosine stress perfusion-CMR. An in-plane spatial resolution of 1.4 × 1.4 mm(2) was achieved by using 5× k-space and time sensitivity encoding (k-t SENSE). Perfusion was visually graded for 1...
متن کاملDetection of Cardiac Artery Disease by Using the DCAD (b) Module
Introduction: In patients with cardiac artery disease, a myocardial perfusion scan, which is a non-invasive method, is utilized. This study is conducted to develop an advantageous software applicable to quantitative myocardial SPECT perfusion. Material and Methods: Each cross-section of the left ventricle was segmented by applying a fuzzy clustering method. After obtaining the myocardial skelet...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2018