The cost-effectiveness of additional preoperative ultrasonography or sestamibi-SPECT in patients with primary hyperparathyroidism and negative findings on sestamibi scans.
نویسندگان
چکیده
OBJECTIVE To determine whether the use of additional preoperative imaging was cost-effective compared with bilateral neck exploration (BNE) for the treatment of primary hyperparathyroidism in patients with negative findings on scans with technetium Tc 99m sestamibi. DESIGN We performed a cost-effectiveness analysis. The decision whether to proceed to BNE or obtain additional preoperative imaging using ultrasonography (US) or single-photon emission computed tomography with technetium Tc 99m sestamibi (SPECT) was modeled using decision analysis. We obtained probabilities of cure, detection of pathologic glands, and the correct side of the neck from recent literature. MAIN OUTCOME MEASURES Expected cost, cure rate, and the incremental cost per cured case using the preoperative imaging strategies compared with BNE. RESULTS The US strategy dominated the SPECT and BNE strategies, with a lower expected cost (USD $6030 vs USD $7131 and $8384, respectively) and a greater expected cure rate (99.42% vs 99.26% and 97.69%, respectively). Threshold analysis suggests that the preoperative imaging strategies continued to dominate unless the cost of BNE was less than USD $5400 or the cost of unilateral neck exploration exceeded USD $6500. The US strategy dominated SPECT as a preoperative imaging strategy if the cost of SPECT exceeded $12 or the cost of a US test was less than $1300. CONCLUSIONS For the treatment of primary hyerparathyroidism in the patient with negative findings on technetium Tc 99m sestamibi scans, a strategy that uses additional preoperative US imaging appears to be cost-effective compared with SPECT or BNE.
منابع مشابه
Parathyroid adenoma Localization
Background: Bilateral neck exploration is the gold standard for parathyroid adenoma localization in primary hyperparathyroidism. But surgeons do not have adequate experience for accurate surgical exploration and new methods are developed for surgery like unilateral exploration and minimally invasive surgery, thus, preoperative localization could reduces time and stress in surgical performance....
متن کاملAn algorithm to maximize use of minimally invasive parathyroidectomy.
HYPOTHESIS Minimally invasive parathyroidectomy (MIP) depends on accurate preoperative localization of abnormal parathyroid glands. If the findings of a technetium Tc 99m sestamibi-labeled single-photon emission computed tomography (SPECT) (hereafter referred to as sestamibi SPECT or scan) are negative or ambiguous, cervical ultrasonography (CUS) may increase the success of preoperative gland l...
متن کاملMinimally invasive/focused parathyroidectomy in patients with negative sestamibi scan results.
OBJECTIVE To examine the feasibility of minimally invasive/focused parathyroidectomy in patients with primary hyperparathyroidism and negative results on preoperative sestamibi scanning. DESIGN Retrospective review. SETTING Hospital. PATIENTS A total of 452 patients with primary hyperparathyroidism underwent parathyroidectomy between January 2005 and December 2009. MAIN OUTCOME MEASURES...
متن کاملPlanar scintigraphy with 123I/99mTc-sestamibi, 99mTc-sestamibi SPECT/CT, 11C-methionine PET/CT, or selective venous sampling before reoperation of primary hyperparathyroidism?
UNLABELLED All patients with primary hyperparathyroidism should undergo localization studies before reoperation, but it is not known which method is most accurate. The purpose of this prospective study was to compare the performance of planar scintigraphy with (123)I/(99m)Tc-sestamibi, (99m)Tc-sestamibi SPECT (SPECT/CT), (11)C-methionine PET/CT, and selective venous sampling (SVS) in persistent...
متن کاملPreoperative ⁹⁹mTc-sestamibi scintigraphy in patients with primary hyperparathyroidism and concomitant nodular goiter: comparison of SPECT-CT, SPECT, and planar imaging.
BACKGROUND Investigations using a hybrid single photon emission computed tomography/computed tomography (SPECT-CT) scanning technique have been carried out in limited studies and have shown mixed results. However, the assessment of this technique for the detection of parathyroid adenoma in patients with a nodular goiter was performed in only one study with a small sample size. The aim of this p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of otolaryngology--head & neck surgery
دوره 132 1 شماره
صفحات -
تاریخ انتشار 2006