The new C3 Gore Excluder stent-graft: single-center experience with 100 patients.

نویسندگان

  • A Katsargyris
  • B Botos
  • K Oikonomou
  • M Pedraza de Leistl
  • W Ritter
  • E L G Verhoeven
چکیده

OBJECTIVES To present results from the first 100 patients treated with the new C3 Gore Excluder stent-graft in a single institution. METHODS All patients treated with the C3 Excluder stent-graft between August 2010 and July 2013 in our institution were included. Patient demographics, treatment indication, need for intraoperative stent-graft repositioning, immediate technical success, survival, endoleak and migration rate, and need for reintervention during follow-up were analyzed. RESULTS A total of 100 patients (86% male, mean age 71.1 ± 9.3 years) were enrolled. Elective abdominal aortic aneurysm (AAA) was the most common indication for treatment (n = 90), followed by common iliac artery aneurysm (n = 5), ruptured AAA (n = 2), type Ia endoleak (n = 1), and type IV endoleak (n = 1) after prior EVAR, and penetrating aortic ulcer (n = 1). Technical success was achieved in 98 patients. In two patients a small type I endoleak persisted at completion angiography, but had disappeared at the first control computed tomography angiogram. Stent-graft repositioning after initial deployment was required in 49 patients, almost equally distributed for level and contralateral gate reorientation. Exact positioning of the proximal trunk was achieved in 98 patients, with the remaining two cases within 5 mm of the intended location. Adverse events related to repositioning maneuvers were noticed in two cases. Mean follow-up duration was 12.2 ± 9.4 months (range 0-36 months). Eight patients died, none from aneurysm related causes. Cumulative patient survival was 96.2 ± 2.1% at 1 year, and 84 ± 6.1% at 2 years, respectively. No migration, or type I or III endoleak was detected during follow-up. Estimated freedom from reintervention was 96 ± 2.4% at 1 year, and 91 ± 5.2% at 2 years, respectively. CONCLUSIONS The new C3 Excluder stent-graft provides excellent short-term outcomes and offers important advantages in terms of stent-graft repositioning to achieve high proximal deployment accuracy. Longer follow-up is required to confirm improved long-term outcome compared with the previous generation Excluder stent-graft.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Technical Tips for Endovascular Aortic Repair Using the Gore Excluder Abdominal Stent-Graft: Endo-Wedge Technique and Scrum Technique

s: When performing endovascular aortic repair (EVAR) procedures, clinicians sometimes encounter cases in which the indications for EVAR are beyond the instruction for use (IFU). In EVAR, proximal neck fixation is the most important factor. This report describes several techniques and tips for EVAR in cases presenting with a difficult short neck or angled neck, especially when using the Gore Exc...

متن کامل

Application of physician-modified fenestrated stent graft in urgent endovascular repair of abdominal aortic aneurysm with hostile neck anatomy

BACKGROUND This study aimed to evaluate the feasibility and effectiveness of the Gore Excluder aortic stent graft (WL Gore & Associates, Inc., Flagstaff, AZ) using the C3 Delivery System after physician modification of fenestration for the urgent treatment of patients with abdominal aortic aneurysm showing hostile neck anatomy. CASE SUMMARY Three urgent cases of abdominal aortic aneurysm with...

متن کامل

Initial Clinical Experience with the Endologix AFX Unibody Stent Graft System for Treating Patients with Abdominal Aortic Aneurysms: A Case Controlled Comparative Study

PURPOSE The newly designed unibody AFX endograft system for endovascular aortic aneurysm repair is the only graft with anatomical fixation to the aortic bifurcation in comparison to most other grafts that use the infrarenal neck as the main fixation point. The aim of this study was to assess the preliminary results of the AFX stent-graft system used with infrarenal aortic component and compare ...

متن کامل

Endovascular repair of bilateral common iliac artery aneurysms using GORE Excluder iliac branch endoprosthesis without aortobi-iliac stent graft conjunction

INTRODUCTION Bilateral common iliac artery (CIA) aneurysm (CIAA) is a rare entity. In the past decade, different endovascular approaches have been adopted for patients with several comorbidities or unfit for open repair (OR). Recently, the use of iliac branch stent graft has been proposed, resulting in satisfactory patency rates and decrease in morbidity. Currently, according to instruction for...

متن کامل

FEATURED TECHNOLOGY: VELATM PROximAL ENDOGRAFT SYSTEm

The rapid acceptance of endovascular repair (EVAR) of abdominal aortic aneurysms (AAAs) over the past 15 years has been driven in large part by advancing endovascular skills, innovation in endograft technology, and physician expansion of the approach to patients with more complex anatomies.1 The challenges to EVAR remain, as is well documented in the clinical literature. Proximal neck morpholog...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery

دوره 47 4  شماره 

صفحات  -

تاریخ انتشار 2014