Estimates of the amount of force exerted by a muscle using electromyography (EMG) rely partially upon the accuracy of the reference point used in the normalization technique. Accurate representations of muscle activities are essential for use in EMG-driven spinal loading models. The expected maximum contraction (EMC) normalization method was evaluated to explore whether it could be used to assess individuals who are not capable of performing a maximum exertion such as a person with a low back injury. Hence, this study evaluated the utility of an EMG normalization method (Marras and Davis, A non-MVC EMG normalization technique, Part 1, method development. Journal of Electromyography and Kinesiology 2000) that draws upon sub-maximal exertions to determine the reference points needed for normalization of the muscle activities. The EMC normalization technique was compared to traditional MVC-based EMG normalization by evaluating the spinal loads for 20 subjects (10 males and 10 females) performing dynamic lifts. The spinal loads (estimated via an EMG-assisted model) for the two normalization techniques were very similar with differences being <8%. The model performance variables indicated that both normalization techniques performed well (r(2)>0.9 and average error below 6%) with only the muscle gain being affected by normalization method as a result in different reference points. Based on these results, the proposed normalization technique was considered to be a viable method for EMG normalization and for use in EMG-assisted models. This technique should permit the quantitative evaluation of muscle activity for subjects unable to produce maximum exertions.
منابع مشابه
A non-MVC EMG normalization technique for the trunk musculature: Part 1. Method development.
Normalization of muscle activity has been commonly used to determine the amount of force exerted by a muscle. The most widely used reference point for normalization is the maximum voluntary contraction (MVC). However, MVCs are often subjective, and potentially limited by sensation of pain in injured individuals. The objective of the current study was to develop a normalization technique that pr...
متن کاملAn EMG-assisted model calibration technique that does not require MVCs.
As personalized biologically-assisted models of the spine have evolved, the normalization of raw electromyographic (EMG) signals has become increasingly important. The traditional method of normalizing myoelectric signals, relative to measured maximum voluntary contractions (MVCs), is susceptible to error and is problematic for evaluating symptomatic low back pain (LBP) patients. Additionally, ...
متن کاملSpine Loading and Probability of Low Back Disorder Risk as a Function of Box Location on a Pallet
It is widely believed that depalletizing operations in manufacturing and service environments substantially increase the risk of occupationally related low back disorders (LBDs). It has been established that the weight of the box lifted off a pallet can affect the risk of occupationally related LBD but few have considered the influence of the location of the box on the pallet (region) when asse...
متن کاملPii: S1050-6411(97)00006-0
Low back disorders (LBDs) are the most common and costly occupationally-related compensable conditions facing employers today. Over the years several biomechanical assessment models have been developed that intended to assess the load profile imposed upon the spine during lifting and, thus, intended to facilitate the control of LBD risk in the workplace. Many of these biomechanical models have ...
متن کاملBiomechanical analysis of functional electrical stimulation on trunk musculature during wheelchair propulsion.
BACKGROUND The objective of this study was to examine how surface electrical stimulation of trunk musculature influences the kinematic, kinetic, and metabolic characteristics, as well as shoulder muscle activity, during wheelchair propulsion. METHODS Eleven participants with spinal cord injury propelled their own wheelchairs on a dynamometer at a speed of 1.3 m/s for three 5-minute trials. Du...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
دوره 11 1 شماره
صفحات -
تاریخ انتشار 2001