Noninvasive determination of exercise-induced hydrodgen ion threshold through direct optical measurement.

نویسندگان

  • Babs R Soller
  • Ye Yang
  • Stuart M C Lee
  • Cassie Wilson
  • R Donald Hagan
چکیده

The intensity of exercise above which oxygen uptake (Vo2) does not account for all of the required energy to perform work has been associated with lactate accumulation in the blood (lactate threshold, LT) and elevated carbon dioxide output (gas exchange threshold). An increase in hydrogen ion concentration ([H+]) is approximately concurrent with elevation of blood lactate and CO2 output during exercise. Near-infrared spectra (NIRS) and invasive interstitial fluid pH (pHm) were measured in the flexor digitorum profundus during handgrip exercise to produce a mathematical model relating the two measures with an estimated error of 0.035 pH units. This NIRS pHm model was subsequently applied to spectra collected from the vastus lateralis of 10 subjects performing an incremental-intensity cycle protocol. Muscle oxygen saturation (SmO2) was also calculated from spectra. We hypothesized that a H+ threshold could be identified for these subjects and that it would be different from but correlated with the LT. Lactate, gas exchange, SmO2, and H+ thresholds were determined as a function of Vo2 using bilinear regression. LT was significantly different from both the gas exchange threshold (Delta = 0.27 +/- 0.29 l/min) and H+ threshold (Delta = 0.29 +/- 0.23 l/min), but the gas exchange threshold was not significantly different from the H+ threshold (Delta = 0.00 +/- 0.38 l/min). The H+ threshold was strongly correlated with LT (R2 = 0.95) and the gas exchange threshold (R2 = 0.85). This initial study demonstrates the feasibility of noninvasive pHm estimations, the determination of H+ threshold, and the relationship between H+ and classical metabolic thresholds during incremental exercise.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Innovative Methodology Noninvasive determination of exercise-induced hydrodgen ion threshold through direct optical measurement

Soller BR, Yang Y, Lee SM, Wilson C, Hagan RD. Noninvasive determination of exercise-induced hydrodgen ion threshold through direct optical measurement. J Appl Physiol 104: 837–844, 2008. First published December 20, 2007; doi:10.1152/japplphysiol.00849.2007.— The intensity of exercise above which oxygen uptake (V̇O2) does not account for all of the required energy to perform work has been assoc...

متن کامل

Detecting abnormalities in left ventricular function during exercise by respiratory measurement.

The degree of exercise-induced cardiac dysfunction and its relation to the anaerobic threshold were evaluated in 23 patients with chronic heart disease. A symptom-limited exercise test was performed with a cycle ergometer with work rate increased by 1 W every 6 seconds. Left ventricular function, as reflected by ejection fraction, was continuously monitored with a computerized cadmium telluride...

متن کامل

Raman Spectra of a PMMA Microstructured Optical Fibre and Direct Measurement of Its Gain Coefficient

 A polymethylmethacrylate (PMMA) microstructured polymer optical fiber (mPOF) is fabricated and characterized. Using the cut-back technique the fiber loss is measured which is higher than the step-index silica fibers. Through a novel experimental scheme, the backward Stokes spectrum of the fabricated mPOF is recorded over a range exceeding 3000 cm‑1 during the cut-back method and compared ...

متن کامل

DESIGN OF A SIMPLE LASER SYSTEM FOR NEPHELOMETRIC DETERMINATION OF ANIONS

A simple analytical system suitable for nephelometric measurements is introduced in this article. The electronic and optical components are simplified so that the apparatus is easily assembled from materials that are generally available. This instrument is designed for the efficient measurement of anions, and microgram quantities of ions may be determined by a convenient method of titration...

متن کامل

Current analytical approaches to measuring blood analytes.

In recent years, laboratory testing in the critical-care setting has increased, a trend due, in part, to the evolution of electrochemical sensors. Various innovations have extended sensor lifetimes, reduced sensor maintenance, and led to the development of single-use and unit-use disposable sensors. These sensor technologies allow the accurate and precise determination, either at or near the be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 104 3  شماره 

صفحات  -

تاریخ انتشار 2008