In Vitro Observation of Air Bubbles during Delivery of Various Detachable Aneurysm Embolization Coils

نویسندگان

  • Deok Hee Lee
  • Seon Moon Hwang
  • Ok Kyun Lim
  • Jae Kyun Kim
چکیده

OBJECTIVE Device- or technique-related air embolism is a drawback of various neuro-endovascular procedures. Detachable aneurysm embolization coils can be sources of such air bubbles. We therefore assessed the formation of air bubbles during in vitro delivery of various detachable coils. MATERIALS AND METHODS A closed circuit simulating a typical endovascular coiling procedure was primed with saline solution degassed by a sonification device. Thirty commercially available detachable coils (7 Axium, 4 GDCs, 5 MicroPlex, 7 Target, and 7 Trufill coils) were tested by using the standard coil flushing and delivery techniques suggested by each manufacturer. The emergence of any air bubbles was monitored with a digital microscope and the images were captured to measure total volumes of air bubbles during coil insertion and detachment and after coil pusher removal. RESULTS Air bubbles were seen during insertion or removal of 23 of 30 coils (76.7%), with volumes ranging from 0 to 23.42 mm(3) (median: 0.16 mm(3)). Air bubbles were observed most frequently after removal of the coil pusher. Significantly larger amounts of air bubbles were observed in Target coils. CONCLUSION Variable volumes of air bubbles are observed while delivering detachable embolization coils, particularly after removal of the coil pusher and especially with Target coils.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endovascular intervention of intradural hemorrhage from ruptured spontaneous vertebral artery dissection.

OBJECTIVE To study the therapeutic effect of endovascular treatment for intradural hemorrhage from ruptured spontaneous vertebral artery dissections (SVAD) using Guglielmi detachable coils and mechanical coils. METHODS The retrospective study was carried out in the Department of Interventional Radiology, Rizhao People`s Hospital, Rizhao, China from January 2008 to December 2011. Twelve patien...

متن کامل

Gas generation and clot formation during electrolytic detachment of Guglielmi detachable coils: in vitro observations and animal experiment.

BACKGROUND AND PURPOSE Recent reports describe a high rate of thromboembolic events related to Guglielmi detachable coil (GDC) use in the treatment of cerebral aneurysms. The purpose of this study was to investigate electrolysis-related changes of blood as a potential cause of thromboembolic complications associated with GDC use. METHODS For in vitro observations, 15 GDCs (10 conventional coi...

متن کامل

Endovascular embolization of unruptured vertebral dissection using Guglielmi electrolytically detachable coils: case report.

We present a patient with unruptured vertebral dissection whose angiograph showed further enlargement of the aneurysm, after a transient reduction in the size of the fusiform dilatation. Tolerance of parent artery occlusion was first confirmed by a balloon occlusion test. Both proximal and distal portions of the vertebral artery, including the dissected site, were occluded using Guglielmi elect...

متن کامل

Retrieval of Distally Migrated Coils with Detachable Intracranial Stent during Coil Embolization of Cerebral Aneurysm

Migration of coils during endovascular procedures is a rare, but well-known complication. We are reporting two cases of successfully retrieving migrated coil using detachable intracranial stent. In both of our cases there was distal migration of coil during the intracranial aneurysm coiling procedure. The Solitaire® AB stent (Covidien, Irvine, CA, USA) was used to retrieve those coils. The sten...

متن کامل

Treatment of intracranial aneurysms by embolization with coils: a systematic review.

BACKGROUND Embolization with coils is increasingly used for the treatment of intracranial aneurysms. To assess the percentage of complications, the percentage of aneurysm occlusion, and the short-term outcome, we performed a systematic review of studies on embolization with controlled detachable or pushable coils. SUMMARY OF REVIEW To find studies on embolization with coils, we performed a ME...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2012