The effect of a recombinant elastin-mimetic coating of an ePTFE prosthesis on acute thrombogenicity in a baboon arteriovenous shunt.

نویسندگان

  • Sumanas W Jordan
  • Carolyn A Haller
  • Rory E Sallach
  • Robert P Apkarian
  • Stephen R Hanson
  • Elliot L Chaikof
چکیده

A recombinant elastin-mimetic triblock protein polymer with an inverse transition temperature (approximately 20 degrees C) was used to impregnate small-diameter (4 mm i.d.) expanded polytetrafluoroethylene (ePTFE) vascular grafts. Scanning electron microscopy confirmed that initial elastin impregnation of the graft followed by further multilayer coating with elastin films filled in the fibril and node structure of the luminal surface of the ePTFE graft and was macroscopically smooth. Elastin protein polymer impregnation reduced the advancing contact angle of the luminal surface to 43 degrees, which was comparable to the advancing contact angle of 47 degrees for a cast elastin film. Attenuated total reflection infrared spectroscopy and Coomassie blue staining revealed little discernable change in the protein surface film after 24 h of shear at 500 s(-1) and 37 degrees C. Excellent short-term blood-contacting properties as determined by minimal fibrin and platelet deposition were demonstrated using a baboon extracorporeal femoral arteriovenous shunt model. The results of this study demonstrate the applicability of an elastin-mimetic triblock protein polymer as a non-thrombogenic coating or as a component of a tissue-engineered composite.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of acute thrombogenicity for metallic and polymeric bioabsorbable scaffolds in a porcine arteriovenous shunt model

number: Euro17A-OP0628 Abstract type: Oral Presentation Reference: This abstract was presented at EuroPCR 2017, 16-19 May 2017, Paris Link: https://abstractbook.pcronline.com/export/pdf/id/628 Published on: 16 May 2017 Comparison of acute thrombogenicity for metallic and polymeric bioabsorbable scaffolds in a porcine arteriovenous shunt model LIPINSKI M.(1)ACAMPADO , E.(2)CHENG , Q.(2)ADAMS , L...

متن کامل

Acute Thrombogenicity of a Durable Polymer Everolimus-Eluting Stent Relative to Contemporary Drug-Eluting Stents With Biodegradable Polymer Coatings Assessed Ex Vivo in a Swine Shunt Model.

OBJECTIVES This study sought to evaluate whether the permanent fluoropolymer-coated Xience Xpedition everolimus-eluting stent (Xience-EES) exhibits lower acute thrombogenicity compared with contemporary drug-eluting stents (DES) with biodegradable polymer coatings in an acute swine shunt model. BACKGROUND Previous pre-clinical and clinical experience suggests that several factors may influenc...

متن کامل

Human Blood Vessel–Derived Endothelial Progenitors for Endothelialization of Small Diameter Vascular Prosthesis

BACKGROUND Coronary bypass graft failure as a result of acute thrombosis and intimal hyperplasia has been the major challenge in surgical procedures involving small-diameter vascular prosthesis. Coating synthetic grafts with patients' own endothelial cells has been suggested to improve the patency rate and overall success of bypass surgeries. METHODOLOGY/PRINCIPAL FINDINGS We isolated endothe...

متن کامل

Thrombotic responses of endothelial outgrowth cells to protein-coated surfaces.

There is significant clinical need for viable small-diameter vascular grafts. While there are many graft biomaterials in development, few have been clinically successful. Evaluation of grafts with a clinically relevant model is needed to drive development. This work examined extracellular matrix coatings on the thrombotic phenotype of endothelial outgrowth cells (EOCs). EOCs were tested on flat...

متن کامل

Effect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis

This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomaterials

دوره 28 6  شماره 

صفحات  -

تاریخ انتشار 2007