Advanced Calibration Method for Pitch Artifact
نویسندگان
چکیده
Abstract − The pitch measuring accuracy for gear measuring instruments (GMIs) is evaluated by measuring a calibrated artifact. We proposed a novel artifact which called multiball artifact (MBA). The MBA is composed of the pitch balls assumed to gear teeth and the reference axis assumed to a center axis of gear. The MBA can be calibrated more accurate than a conventional pitch artifact. When the MBA is calibrated, it is important to eliminate an error of measuring instrument; therefore we calibrate the MBA adapting the multiple-orientation technique. In the multipleorientation technique, the MBA is set up in difference orientations around the reference axis and the measurement error is eliminates by averaging the measurement value for all orientations. There are, however, Fourier components of the measurement error that can not be eliminated depending on the total number of orientations. In this paper, we propose the advanced calibration method; the error separation method for the multiple-orientation technique is improved and the total number of orientations can be reduced. The superiority of the proposed method is clarified from the calibration results using the MBA.
منابع مشابه
A New Compensation Method for Measurement of Thread Pitch Diameter by Profile Scanning
For measurement of existing thread parameters using profile scanning, system error increases as pitch diameter, difference between the calibrating thread and measuring thread increases with the single gauge calibration method. There are several alignment deviations affecting the measurement of pitch diameter. To reduce the system error, a compensation method using two standard thread gauges to ...
متن کاملValidation of ATMS Calibration Accuracy Using Suomi NPP Pitch Maneuver Observations
The Suomi National Polar-orbiting Partnership (SNPP) satellite was launched on 28 October, 2011, and carries the Advanced Technology Microwave Sounder (ATMS) onboard. Currently, ATMS performance in orbit is very stable and the calibration parameters (e.g., noise and accuracy) meet specifications. This study documents an ATMS calibration error budget model and its results for community reference...
متن کاملReduction of breathing irregularity-related motion artifacts in low-pitch spiral 4D CT by optimized projection binning
BACKGROUND Respiration-correlated CT (4D CT) is the basis of radiotherapy treatment planning of thoracic and abdominal tumors. Current clinical 4D CT images suffer, however, from artifacts due to unfulfilled assumptions concerning breathing pattern regularity. We propose and evaluate modifications to existing low-pitch spiral 4D CT reconstruction protocols to counteract respective artifacts. ...
متن کاملFull parameter calibration of parallel mechanism
Calibration of a parallel mechanism using a specified artifact, artifact calibration, is an effective method. However, there are strong correlations between each parameter in an artifact calibration of a parallel mechanism. Therefore, it is difficult to identify all kinematic parameters included in a kinematic model of the parallel mechanism from measuring data. In this research, we propose two...
متن کاملA New Method for Metal Artifact Reduction in CT Scan Images
Introduction In CT imaging, metallic implants inside the tissues cause metal artifact that reduce the quality of image for diagnosis. In order to reduce the effect of this artifact, a new method with more appropriate results has been presented in this research work. Materials and Methods The presented method comprised of following steps: a) image enhancement and metal areas extraction, b) sinog...
متن کامل