Determination of sulpiride by capillary electrophoresis with end-column electrogenerated chemiluminescence detection.

نویسندگان

  • Jifeng Liu
  • Weidong Cao
  • Haibo Qiu
  • Xiuhua Sun
  • Xiurong Yang
  • Erkang Wang
چکیده

BACKGROUND Capillary electrophoresis (CE) with tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)3(2+)]-electrogenerated chemiluminescence (ECL) detection is a promising method for clinical analysis. In this study, a method combining CE with Ru(bpy)3(2+) ECL (CE-ECL) detection that can be applied to amine-containing clinical species was developed, and the performance of CE-ECL as a quantitative method for determination of sulpiride in human plasma or urine was evaluated. METHODS Sulpiride was separated by capillary zone electrophoresis in uncoated fused-silica capillaries [50 cm x 25 microm (i.d.)] filled with phosphate buffer (pH 8.0) and a driving voltage of +15 kV, with end-column Ru(bpy)3(2+) ECL detection. A platinum disc electrode was used as working electrode. Sulpiride in human plasma or urine samples (100 microL) was extracted by a double-step liquid-liquid extraction procedure, dried under nitrogen at 35 degrees C in a water bath, and reconstituted with 100 microL of filtered water. The extraction solvent was ethyl acetate-dichloromethane (5:1 by volume). RESULTS Under optimum conditions (pH 8.0 phosphate buffer, injection for 6 s at 10 kV, and +1.2 V as detection potential), separation of sulpiride was accomplished within 4 min. The calibration curve was linear over a concentration range of 0.05-25.0 micromol/L, and the limit of detection was 2.9 x 10(-8) mol/L for sulpiride. Intra- and interday CVs for ECL intensities were <6%. Extraction recoveries of sulpiride were 95.6-101% with CVs of 2.9-6.0%. The method was clinically validated for patient plasma and urine samples. CONCLUSIONS CE combined with Ru(bpy)3(2+) ECL is reproducible, precise, selective, and enables the analysis of sulpiride in human plasma and urine. It thus is of value for rapid and efficient analysis of amine-containing analytes of clinical interest.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of monosaccharides by capillary electrophoresis with electrochemiluminescence detection.

A capillary electrophoresis with tris(2,2'-bipyridyl)ruthenium(II)-based electrogenerated chemiluminescence detection method was investigated for the determination of monosaccharides using 2-diethylaminoethanethiol as a derivatizing reagent. Xylose, rhamnose, glucose and glucosamine were selected for the demonstration of the method. Under optimal conditions, the calibration curve of glucose was...

متن کامل

Simultaneous electrochemiluminescence determination of sulpiride and tiapride by capillary electrophoresis with cyclodextrin additives.

Sulpiride and tiapride are often used in the treatment of depression, schizophrenia and psychopathology of senescence, gastric or duodenal ulcers and are also partly excreted by kidney. This work developed a simple and sensitive method for their simultaneous monitoring in human urine based on capillary electrophoresis coupled with electrochemiluminescence detection by end-column mode. beta-Cycl...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

Column-switching HPLC determination of mexiletine using tris(bipyridine)ruthenium(III) electrogenerated chemiluminescence and precolumn derivatization with divinylsulfone.

A sensitive HPLC method combined with a column-switching system and tris(bipyridine)ruthenium(III) electrogenerated chemiluminescence (ECL) detection has been developed for the quantitative determination of mexiletine (MEX). MEX was derivatized by divinylsulfone (DVS) and then measured. The optimum conditions for the derivatization reaction were 10 µL of sample solutions, 40 mM DVS (pH 8.0), a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 48 7  شماره 

صفحات  -

تاریخ انتشار 2002