Dosimetric uncertainties related to the elasticity of bladder and rectal walls: adenocarcinoma of the prostate.
نویسندگان
چکیده
PURPOSE Radiotherapy is an important treatment for prostate cancer. During treatment sessions, bladder and rectal repletion is difficult to quantify and cannot be measured with a single and initial CT scan acquisition. Some methods, such as image-guided radiation therapy and dose-guided radiation therapy, aim to compensate this missing information through periodic CT acquisitions. The aim is to adapt patient's position, beam configuration or prescribed dose for a dosimetric compliance. METHODS We evaluated organ motion (and repletion) for 54 patients after having computed the original ballistic on a new CT scan acquisition. A new delineation was done on the prostate, bladder and rectum to determine the new displacements and define organ doses mistakes (equivalent uniform dose, average dose and dose-volume histograms). RESULTS The new CT acquisitions confirmed that bladder and rectal volumes were not constant during sessions. Some cases showed that previously validated treatment plan became unsuitable. A proposed solution is to correct dosimetries when bladder volume modifications are significant. The result is an improvement for the stability of bladder doses, D50 error is reduced by 25.3%, mean dose error by 5.1% and equivalent uniform dose error by 2.6%. For the rectum this method decreases errors by only 1%. This process can reduce the risk of mismatch between the initial scan and following treatment sessions. CONCLUSION For the proposed method, the cone-beam CT is necessary to properly position the isocenter and to quantify bladder and rectal volume variation and deposited doses. The dosimetries are performed in the event that bladder (or rectum) volume modification limits are exceeded. To identify these limits, we have calculated that a tolerance of 10% for the equivalent uniform dose (compared to the initial value of the first dosimetry), this represents 11% of obsolete dosimetries for the bladder, and 4% for the rectum.
منابع مشابه
The effects of volumetric changes on radiation doses of the rectum and bladder during radiotherapy in patients with prostate cancer
Background: In prostate radiotherapy, changes in the volume of the bladder and rectum can influence dose delivery. In this study, cone-beam computerised tomography (CBCT) imaging was used to assess volumetric, and corresponding radiation dosimetric changes, for the bladder and rectum in patients with prostate cancer treated using VMAT. Materials and Methods: Treatment planning computed tomograp...
متن کاملDosimetric Comparison of Various Radiotherapeutic Treatment Plans Using Cobalt-60 and Linac for Prostate Cancer
Introduction: This study was designed to evaluate dosimetric parameters such as rectal dose, bladder dose, integral dose (ID), homogeneity index (HI) and conformity index (CI) in various treatment plans for prostate cancer. Materials and Methods: Pelvic computed tomography (CT) scans of 27 patients were acquired and transferred to the RTDosePLAN treatment planning system. For each patient, 8 co...
متن کاملThe effect of Rectal Retractor, a rectal protector on rectal dose in radical prostate radiotherapy
Introduction: The close proximity of the rectum tissue to the prostate gland results in rectal toxicity during prostate radiotherapy. Rectal Retractor (RR) is a rectal displacement technique that inserts into the rectum, as a result, the lateral and dorsal part of the rectal wall push away from high dose areas. The aim of this study was to investigate the dosimetric consequence...
متن کاملDosimetric influence of Flattening Filter (FF) and Flattening Filter Free (FFF) 6 and 10 MV photon beams on Volumetric Modulated Arc Therapy (VMAT) planning in case of prostate carcinoma
Background: In the treatment of prostate cancer, radiotherapy is the potential to increase second primary cancers such as bladder and rectal cancers. The reasons for this potential are more monitor units (MUs), therefore a larger total body dose because of leakage radiation, a bigger volume of normal tissue is exposed to lower radiation doses. This study was designed to compare the integral dos...
متن کاملAnalysis of Hip Joint Dose in Prostate Cancer Radiation Therapy: A Dosimetric Comparison of Treatment Plans
Background and purpose: Radiation therapy as a part of cancer treatment is used in almost 50-60% of involved cases. In prostate cancer radiation therapy, a large volume of pelvis is irradiated, so, it is necessary to preserve sensitive organs around the treatment area, especially rectum and bladder. In this study, some dosimetric parameters such as minimum dose (Dmin), maximum dose (Dmax), mean...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique
دوره 15 4 شماره
صفحات -
تاریخ انتشار 2011