Minimally Invasive Pedicle Screw Fixation Using Intraoperative 3-dimensional Fluoroscopy-based Navigation (CAMISS Technique) for Hangman Fracture.

نویسندگان

  • Zhao Lang
  • Wei Tian
  • Yajun Liu
  • Bo Liu
  • Qiang Yuan
  • Yuzhen Sun
چکیده

STUDY DESIGN Retrospective comparative cohort series. OBJECTIVE To evaluate the accuracy and feasibility of minimally invasive surgical (MIS) techniques incorporating with intraoperative 3-dimensional fluoroscopy-based navigation (ITFN) for treating Hangman fracture. SUMMARY OF BACKGROUND DATA MIS screw fixation for Hangman fracture can decrease iatrogenic soft-tissue injury, but increase the risk of instrumentation-related complications due to lack of anatomical landmarks. With the advantages of obtaining intraoperative real-time images, automatic registration, and 3-dimensional views, the ITFN system seems to be an inherent partner for MIS. METHODS 20 patients with Hangman fracture underwent C2-C3 pedicle screw fixation using ITFN. 6 patients used MIS technique, with the other 14 patients using conventional open technique. Operative time and blood loss were recorded. The accuracy of screw positions was studied by postoperative CT scan. Neck pain visual analogue score (VAS) was evaluated and the fusion status was ascertained in 6-month follow-up. RESULTS The average operative time was 134.2 ± 8.0 minutes in computer-assisted orthopaedics surgery (CAOS)-MIS group and 139.3 ± 25.8 minutes in CAOS-open group (P > 0.01). The blood loss was 66.7 ± 25.8 mL in CAOS-MIS group and 250.0 ± 141.4 mL in CAOS-open group (P < 0.01). A total of 80 screws were inserted. No screw-related neurovascular injury was observed. 83.3% (20/24) screws in CAOS-MIS group and 89.3% (50/56) screws in CAOS-open group were grade 1 screw (P > 0.01). No grade 3 screw was detected in both groups. Compared with the CAOS-open group (1.7 ± 0.6), neck pain VAS in 6-month follow-up in CAOS-MIS group (0.3 ± 0.5) was significantly lower (P < 0.01). Solid fusion was demonstrated in all the cases. CONCLUSION The integration of these 2 techniques MIS and ITFN, we call "computer assisted minimally invasive spinal surgery," is proved to be feasible and safe for treating Hangman fracture with the advantage of significantly reduced iatrogenic soft tissue injury. So we think CAMISS technique represents the most recent modification of spine surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electromagnetic Navigation in Minimally Invasive Spine Surgery: Results of a Cadaveric Study to Evaluate Percutaneous Pedicle Screw Insertion

BACKGROUND This cadaveric study compared efficacy and safety of an electromagnetic (EM) guidance system versus conventional fluoroscopy for percutaneous pedicle screw fixation. As percutaneous pedicle screw fixation becomes increasingly common in spinal surgery, intraoperative imaging systems that maximize efficiency while minimizing radiation exposure and inaccurate trajectories will be progre...

متن کامل

Clinical Results of Percutaneous Fixation of Pelvic and Acetabular Fractures: A Minimally Invasive Internal Fixation Technique

Background: The pelvic ring fractures (PRF) and acetabular fractures (AF) are among the major orthopedic injuriesassociated with high rates of morbidity and mortality. Open surgical stabilization is the standard treatment for themajority of these complications. Percutaneous minimally invasive surgical stabilization of the fractures has become anaccepted treatment method for th...

متن کامل

Comparison of Isocentric C-Arm 3-Dimensional Navigation and Conventional Fluoroscopy for Percutaneous Retrograde Screwing for Anterior Column Fracture of Acetabulum

Percutaneous screw insertion for minimally displaced or reducible acetabular fracture using x-ray fluoroscopy and computer-assisted navigation system has been advocated by some authors. The purpose of this study was to compare intraoperative conditions and clinical results between isocentric C-arm 3-dimensional (Iso-C 3D) fluoroscopy and conventional fluoroscopy for percutaneous retrograde scre...

متن کامل

The surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring – a retrospective review of 627 screws in 150 patients

OBJECTIVE This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly positioned screws were reviewed in the context of the surgeon's experience and learning curve. MET...

متن کامل

Surgical Navigation Technology Based on Augmented Reality and Integrated 3D Intraoperative Imaging

STUDY DESIGN A cadaveric laboratory study. OBJECTIVE The aim of this study was to assess the feasibility and accuracy of thoracic pedicle screw placement using augmented reality surgical navigation (ARSN). SUMMARY OF BACKGROUND DATA Recent advances in spinal navigation have shown improved accuracy in lumbosacral pedicle screw placement but limited benefits in the thoracic spine. 3D intraope...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 41 1  شماره 

صفحات  -

تاریخ انتشار 2016