A rapid "side-room" method for the determination of plasma fibrinogen concentration as fibrin.

نویسندگان

  • G I INGRAM
  • M O MATCHETT
چکیده

A method is proposed for the rapid estimation of plasma fibrinogen concentration. The technique depends on the increase of optical density occurring when plasma clots. A kit is described which obviates the use of laboratory apparatus, so that the test may be performed in the ward side-room if a small centrifuge can be provided.A calibration curve has been prepared for use with commercial opacity standards, and a measure of the error of the method has been obtained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation of Plasminogen by Affinity Chromatography

Background: Plasminogen is one of the compounds derived from human plasma. Activation of plasminogen produces plasmin. Plasmin is able to lyse fibrinogen, fibrin, and some other human plasma proteins. The aim of the present work was to study the separation of human plasminogen by affinity chromatography using gel lysine Sepharose. Materials and Methods: Normal human plasma was used as the...

متن کامل

Plasma Fibrinogen and D-dimer in Children With Sepsis: A Single-center Experience

Background & Objectives:  In sepsis, enhanced fibrin formation, impaired fibrin degradation, and intravascular fibrin deposition lead to a prothrombotic state. The current study aimed at measuring various coagulation parameters to predict an early marker for disseminated intravascular coagulation (DIC). Methods: The current prospective s...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

Rapid measurement of fibrinogen concentration in whole blood using a steel ball coagulometer

BACKGROUND Fibrinogen plays a key role in hemostasis and is the first coagulation factor to reach critical levels in bleeding patients. Current European guidelines on the management of traumatic or perioperative bleeding recommend fibrinogen supplementation at specific threshold levels. Whole blood viscoelastic tests provide fast evaluation of fibrin deficits. Fast measurement of plasma fibrino...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 13  شماره 

صفحات  -

تاریخ انتشار 1960