Double-grating monochromatic beamline with ultrafast response for FLASH2 at DESY

نویسندگان

  • Luca Poletto
  • Fabio Frassetto
  • Günter Brenner
  • Marion Kuhlmann
  • Elke Plönjes
چکیده

The preliminary design of a monochromatic beamline for FLASH2 at DESY is presented. The monochromator is tunable in the 50-1000 eV energy range with resolving power higher than 1000 and temporal response below 50 fs over the whole energy range. A time-delay-compensated configuration using the variable-line-spacing monochromator design with two gratings is adopted: the first grating disperses the radiation on its output plane, where the intermediate slit performs the spectral selection; the second grating compensates for the pulse-front tilt and for the spectral dispersion due to diffraction from the first grating.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double-grating Monochromator for Ultrafast Free- Electron-laser Beamlines

We present the design of an ultrafast monochromator explicitly designed for extreme-ultraviolet FEL sources, in particular the upcoming FLASH II at DESY. The design originates from the variable-line-spaced (VLS) grating monochromator by adding a second grating to compensate for the pulse-front tilt given by the first grating after the diffraction. The covered spectral range is 6-60 nm, the spec...

متن کامل

HARWI-II, The New High-Energy Beamline for Materials Science at HASYLAB / DESY

Abstract. The GKSS Forschungszentrum Geesthacht, Germany, will setup a new high-energy beamline specialized for texture, strain and imaging measurements for materials science at the Hamburger Synchrotronstrahlungslabor HASYLAB of the Deutsches Elektronen-Synchrotron DESY. Four different experiments will be installed at the new wiggler HARWI-II. The high pressure cell will be run by the GFZ Pots...

متن کامل

Upgrade of beamline BL08B at Taiwan Light Source from a photon-BPM to a double-grating SGM beamline.

During the last 20 years, beamline BL08B has been upgraded step by step from a photon beam-position monitor (BPM) to a testing beamline and a single-grating beamline that enables experiments to record X-ray photo-emission spectra (XPS) and X-ray absorption spectra (XAS) for research in solar physics, organic semiconductor materials and spinel oxides, with soft X-ray photon energies in the range...

متن کامل

Diffraction gratings metrology and ray-tracing results for an XUV Raman spectrometer at FLASH

The extreme-ultraviolet double-stage imaging Raman spectrometer is a permanent experimental endstation at the plane-grating monochromator beamline branch PG1 at FLASH at DESY in Hamburg, Germany. This unique instrument covers the photon energy range from 20 to 200 eV with high energy resolution of about 2 to 20 meV (design values) featuring an efficient elastic line suppression as well as effec...

متن کامل

Temporal Response of Ultrafast Grating Monochromators

The temporal response of double-grating monochromators is analyzed considering two effects on the ultrafast pulse given by the configuration. The first effect is the compensation of the pulse-front tilt, i.e., all the rays emitted by the source in different directions at the same wavelength have to travel the same optical path. The second effect is the group delay introduced by the two gratings...