Quantification of relative coronary arterial stenosis by cinevideodensitometric analysis of coronary arteriograms.

نویسندگان

  • A B Nichols
  • C F Gabrieli
  • J J Fenoglio
  • P D Esser
چکیده

A computerized method for measuring relative coronary arterial stenosis by cinevideodensitometric analysis of 35 mm coronary arteriograms was developed and validated. Video images of projected coronary arteriographic frames were digitized into a 512 X 512 matrix (256 gray levels) by computer analysis that compared integrated contrast density measured over stenotic and normal arterial segments after background subtraction. Pixel density was 70 to 80 pixels/mm2 actual area. In phantom studies performed on plexiglass cylinders, cinevideodensitometric measurements correlated linearly with concentration of contrast medium (r = .99), with cross-sectional areas (r = .99) of contrast-filled cylinders 1 to 4 mm in diameter over a wide range of contrast concentrations (25% to 100%), and with relative stenosis of eccentric lesions in the cylinders (r = .99, SEE = 3.9%). In postmortem studies of patients who died after undergoing coronary arteriography, videodensitometric measurements of relative stenosis correlated highly (r = .97, SEE = 7.0%) with percentage stenosis based on actual area measurements obtained histologically with computer-assisted microscopic planimetry. Cinevideodensitometric analysis of coronary arteriograms was reproducible (r = .92, SEE = 7.7%), and interobserver variability was low (r = .99, SEE = 4.3%). In addition, videodensitometry provided comparable values for eccentric coronary lesions filmed in right anterior oblique and left anterior oblique projections (r = .99, SEE = 1.9%). Cinevideodensitometric analysis is an accurate, rapid method for quantifying the relative stenosis of eccentric coronary lesions without manual tracing of arterial borders.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Methods Coronary Artery Disease

A computerized method for measuring relative coronary arterial stenosis by cinevideodensitometric analysis of 35 mm coronary arteriograms was developed and validated. Video images of projected coronary arteriographic frames were digitized into a 512 x 512 matrix (256 gray levels) by computer analysis that compared integrated contrast density measured over stenotic and normal arterial segments a...

متن کامل

BRIEF REVIEW Quantification of Coronary Artery Stenosis in Vivo

VISUAL interpretations of coronary arteriograms are marked by such great interobserver and intraobserver variability (Bjork et al., 1975; Detre et al., 1975; Zir et al., 1976; DeRouen et al., 1977; Meyers et al., 1978) that comparison of arteriograms from different subjects, or at different times in the same subject, are of limited value for assessing severity, changes in severity, or functiona...

متن کامل

Directional low-pass filtering for improved accuracy and reproducibility of stenosis quantification in coronary arteriograms

Considers the quantification of percent diameter stenosis in digital coronary arteriograms of low spatial resolution. To improve accuracy and reproducibility an edge-preserving smoothing method, called the directional low-pass filter (DLF), was developed to suppress quantum noise by averaging image intensity in a direction parallel to the vessel border. Accuracy of stenosis quantification was a...

متن کامل

The association between small dense low density lipoprotein,apolipoprotein B, apolipoprotein B/apolipoprotein A1 ratio and coronary artery stenosis

  Abstract   Background: Recently, small dense low density lipoprotein (sdLDL) has been   highlighted as a new risk factor for the coronary artery disease (CAD).Small dense   LDLs are believed to be atherogenic since these particles are taken up more easily by   arterial wall. They are readily oxidized and have reduced affinity for low density   lipoprotein (LDL) receptor and increased affinity...

متن کامل

سطح LDL کوچک و چگال، لیپید‌ها و لیپوپروتئین‌ها در بیماران مبتلا به گرفتگی عروق کرونر و افراد سالم

  Background & Aim :Low density lipoprotein (LDL) particles are heterogenous with respect to their size,density and lipid composition. Among LDL particles ,the smaller and denser LDLs (small dense (sd)LDL) are believed to be atherogenic since these particles are taken up more easily by arterial wall.They are readily oxidized and have reduced affinity for LDL receptor and increased affinity for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 69 3  شماره 

صفحات  -

تاریخ انتشار 1984