Oral Factors Affecting Titanium Elution and Corrosion: An In Vitro Study Using Simulated Body Fluid
نویسندگان
چکیده
OBJECTIVES Ti, which is biocompatible and resistant to corrosion, is widely used for dental implants, particularly in patients allergic to other materials. However, numerous studies have reported on Ti allergy and the in vitro corrosion of Ti. This study investigated the conditions that promote the elution of Ti ions from Ti implants. METHODS Specimens of commercially pure Ti, pure nickel, a magnetic alloy, and a gold alloy were tested. Each specimen was immersed in a simulated body fluid (SBF) whose pH value was controlled (2.0, 3.0, 5.0, 7.4, and 9.0) using either hydrochloric or lactic acid. The parameters investigated were the following: duration of immersion, pH of the SBF, contact with a dissimilar metal, and mechanical stimulus. The amounts of Ti ions eluted were measured using a polarized Zeeman atomic absorption spectrophotometer. RESULTS Eluted Ti ions were detected after 24 h (pH of 2.0 and 3.0) and after 48 h (pH of 9.0). However, even after 4 weeks, eluted Ti ions were not detected in SBF solutions with pH values of 5.0 and 7.4. Ti elution was affected by immersion time, pH, acid type, mechanical stimulus, and contact with a dissimilar metal. Elution of Ti ions in a Candida albicans culture medium was observed after 72 h. SIGNIFICANCE Elution of Ti ions in the SBF was influenced by its pH and by crevice corrosion. The results of this study elucidate the conditions that lead to the elution of Ti ions in humans, which results in implant corrosion and Ti allergy.
منابع مشابه
Characterization and Corrosion Behavior of Hydroxyapatite- Coated Titanium Substrates Prepared Through Laser Induced Liquid Deposition Technique
Titanium and titanium alloys are often used in orthopedic surgery and dentistry because of their especial characteristics such as biocompatibility, mechanical properties, and corrosion resistance. However, their bio- inertness is the most serious drawback for biomedical applications. Therefore, a bioactive coating like hydroxyapatite (HA) is coated on their surface. In this regard, in the prese...
متن کاملEffect of coating time on the corrosion behavior of ceramic coatings containing hydroxyapatite nanoparticles by plasma electrolytic oxidation method on AZ31 Mg alloy in simulated body fluid
In this study, the effect of coating time on the microstructure and corrosion behavior of AZ31 Mg alloy coated by plasma electrolytic oxidation (PEO) method has been investigated. For this purpose, phosphate-based electrolyte containing hydroxyapatite nanoparticles was used at different times of 5, 10 and 15 minutes. The surface properties and chemical composition of the coatings were investiga...
متن کاملEFFECT OF ANODIC OXIDATION ON THE CORROSION BEHAVIOR OF NICKEL-TITANIUM SHAPE MEMORY ALLOYS IN SIMULATED BODY FLUIDS (SBF)
The effect of anodic oxidation of a NiTi shape memory alloy in sulfuric acid electrolyte on its surface characteristics was studied. Surface roughness was measured by roughness tester. Surface morphology was studied using optical microscopy (OM) and scanning electron microscopy (SEM). Corrosion behavior was specified by recording Potentiodynamic polarization cur...
متن کاملCorrosion Behavior of Ti/TiN Multilayer Nanostructured Coatings Applied on AISI 316L by Arc-PVD Method in the Simulated Body Fluid
In this investigation, Ti/TiN nanolayer and TiN single layer coatings were coated on substrate of AISI 316L stainless steel by applying physical vapor deposition (PVD) using the type of cathodic arc evaporation (CAE). The evaluation of microstructure were carried out using x-ray diffraction (XRD), nanoindentation, atomic force microscopy (AFM) as well as scanning electron microscopy (SEM). Pola...
متن کاملIn vitro biocompatibility response of Ti–Zr–Si thin film metallic glasses
In this study, the bio-electrochemical response of the Ti–Zr–Si thin film metallic glasses (TFMGs) in simulated body fluid with different contents of titanium is measured via potentiostat. According to the results of bio-corrosion potential and current, as well as the polarization resistance, it is concluded that the Ti66Zr25Si9 TFMGs possess the highest bio-electrochemical resistance. With inc...
متن کامل