Correlation between echocardiographically demonstrated segmental dyskinesis and regional myocardial perfusion.

نویسندگان

  • R E Kerber
  • M L Marcus
  • J Ehrhardt
  • R Wilson
  • F M Abboud
چکیده

In order to evaluate the relationship between regional myocardial perfusion and segmental dyskinesis, 22 open chest dogs were studied using ultrasound to register cardiac wall motion and radioactive labeled microspheres to determine myocardial perfusion. In six dogs, motion and perfusion were correlated at two levels of partial circumflex coronary artery occlusion followed by complete occlusion. A good correlation between declining myocardial perfusion of all the ischemic segments and development of aneurysmal bulging (during isometric contraction) was seen: r = minus 0.80. A similar correlation between myocardial perfusion and endocardial wall velocity (during systolic ejection) was observed: r = 0.92. In nine dogs, the effect of 45 minutes of complete coronary occlusion followed by 30 minutes of reperfusion was evaluated with respect to perfusion and motion. After coronary reperfusion myocardial perfusion of the ischemic area returned to control levels (from 32.6 +/- 3.5 to 130.3 +/- 13.3 ml/100 g/min), but aneurysmal bulging during isometric contraction persisted. Endocardial wall velocity during systolic ejection showed a variable response to reperfusion, achieving values ranging from 32% to 162% of the preocclusion levels. In seven dogs the ultrasound beam was reflected off nonischemic myocardium adjacent to areas of ischemia resulting from coronary occlusion. Despite preservation of normal myocardial perfusion in these nonischemic areas wall motion abnormalities were evident: endocardial wall velocity declined from 25.8 +/- 5.8 to 14.0 +/- 4.9 mm/sec (P less than 0.01), and aneurysmal bulging in three animals. These changes may be due to transient undetected ischemia in the segments struck by the ultrasound beam, or to passive alteration of the motion of the normally perfused areas by the severe dyskinesis of the adjacent ischemic myocardium.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis

Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT.  We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress  score (SSS), summed rest score (SRS) and summed difference score (SDS). ...

متن کامل

Two-dimensional echocardiographic recognition of myocardial injury in man: comparison with postmortem studies.

To assess the accuracy of phased-array two-dimensional echocardiography in detecting, localizing and quantifying myocardial injury in man, the relationship of two-dimensional echocardiographic wall motion abnormalities to morphologic evidence of myocardial infarction was evaluated in 20 autopsied patients. Comparisons were made between independent two-dimensional echocardiographic readings of l...

متن کامل

Enhancement of regional myocardial efficiency and persistence of perfusion, oxidative, and functional reserve with paired pacing of stunned myocardium.

BACKGROUND Stunned myocardium reflects postreperfusion dysfunction in myocardium that is destined to ultimately fully recover. Most investigators attribute postreperfusion stunning to a primary defect in excitation-contraction coupling or to an altered sensitivity of the myofilaments to calcium. The aim of the present study was to evaluate the interrelation between myocardial perfusion, oxidati...

متن کامل

Myocardial perfusion and viability by positron emission tomography in infants and children with coronary abnormalities: correlation with echocardiography, coronary angiography, and histopathology.

OBJECTIVES This study was designed to assess the feasibility and accuracy of positron emission tomography (PET) imaging in infants and children. BACKGROUND Positron emission tomography is employed in adults for the evaluation of myocardial perfusion and the detection of myocardial viability. METHODS Perfusion and metabolism findings on PET in infants and children with suspected coronary abn...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 52 6  شماره 

صفحات  -

تاریخ انتشار 1975