OBJECTIVES The aim of this study was to evaluate two commonly used advanced bipolar devices (ENSEAL(®) G2 Tissue Sealers and LigaSure™ Blunt Tip) for compression uniformity, vessel sealing strength, and consistency in bench-top analyses. METHODS Compression analysis was performed with a foam pad/sensor apparatus inserted between closed jaws of the instruments. Average pressures (psi) were recorded across the entire inside surface of the jaws, and over the distal one-third of jaws. To test vessel sealing strength, ex vivo pig carotid arteries were sealed and transected and left and right (sealed) halves of vessels were subjected to burst pressure testing. The maximum bursting pressures of each half of vessels were averaged to obtain single data points for analysis. The absence or presence of tissue sticking to device jaws was noted for each transected vessel. RESULTS Statistically higher average compression values were found for ENSEAL(®) instruments (curved jaw and straight jaw) compared to LigaSure™, P<0.05. Moreover, the ENSEAL(®) devices retained full compression at the distal end of jaws. Significantly higher and more consistent median burst pressures were noted for ENSEAL(®) devices relative to LigaSure™ through 52 firings of each device (P<0.05). LigaSure™ showed a significant reduction in median burst pressure for the final three firings (cycles 50-52) versus the first three firings (cycles 1-3), P=0.027. Tissue sticking was noted for 1.39% and 13.3% of vessels transected with ENSEAL(®) and LigaSure™, respectively. CONCLUSION In bench-top testing, ENSEAL(®) G2 sealers produced more uniform compression, stronger and more consistent vessel sealing, and reduced tissue sticking relative to LigaSure™.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laparoscopic vessel sealing technologies.

Laparoscopic vessel sealing devices have revolutionized modern laparoscopy. These devices fall into 2 major categories: advanced bipolar and ultrasonic instruments. The range of tissue effects available with these technologies is more limited than with conventional monopolar electrosurgery; however, both advanced bipolar and ultrasonic devices efficiently seal vessels (≤7-mm and ≤5-mm diameter,...

متن کامل

Use of a Bipolar Blood-Sealing System During Total Joint Arthroplasty.

The goal of the clinical use of a bipolar blood-sealing system is to reduce perioperative blood loss in total joint arthroplasty (TJA). This study was performed to determine whether a bipolar sealer is safe and effective in TJA and whether there are any advantages over monopolar sealers. The authors searched electronic databases and reference lists of relevant articles; retrieved all published ...

متن کامل

Influence of Er:YAG laser irradiation on apical sealing of four different sealers.

The sealing of the root canal system is of fundamental importance for successful endodontic treatment. To obtain an adequate apical seal, many factors must be considered such as the presence of smear layer and the sealer applied. After canal preparation, this layer must be removed because it prevents close contact between the dentinal walls and the sealing material. The goal of this study was t...

متن کامل

Evaluation of Sealing Ability of Three Root Canal Sealers

The purpose of this study was to determine the sealing ability of three different sealers and to compare the sealing ability of three sealers. Thirty single rooted mandibular first premolar teeth were used. The crowns were removed at the cemento -enamel junction and root canals were prepared to a # 35 K-file. The teeth were randomly divided into three groups, A, K and R. Each group consisted of...

متن کامل

The effect of irrigation solutions on the apical sealing ability in different root canal sealers.

The aim of this study was to assess the effect of three root canal irrigation solutions on the apical sealing ability of three root canal obturation materials: gutta-percha/AH plus or MM-seal and Resilon/Epiphany SE. A total of 100 teeth with single straight root canals were randomly divided into three equal groups of 30 samples each, with the other 10 teeth (5 positive and 5 negative) used as ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2015