Predictors of Technical Success and Rate of Complications of Image-Guided Percutaneous Transthoracic Lung Needle Biopsy of Pulmonary Tumors
نویسندگان
چکیده
PURPOSE To investigate predictors of technical success and complications of computed tomography (CT)-guided percutaneous transthoracic needle biopsy of potentially malignant pulmonary tumors. MATERIAL AND METHODS From 2008 to 2009, technical success and rate of complications of CT-guided percutaneous transthoracic lung needle biopsies of patients with suspicious pulmonary tumors were retrospectively evaluated. The influence on technical success and rate of complications was assessed for intervention-related predictors (lesion diameter, length of biopsy pathway, number of pleural transgressions, and needle size) and patient-related predictors (age, gender, reduced lung function). In addition, technical success and rate of complications were compared between different interventional radiologists. RESULTS One hundred thirty-eight patients underwent biopsies by 15 interventional radiologists. The overall technical success rate was 84.1% and was significantly different between interventional radiologists (range 25%-100%; p<0.01). Intervention-related and patient-related predictors did not influence the technical success rate. The overall complication rate was 59.4% with 39.1% minor complications and 21.0% major complications. The rate of complications was influenced by lesion diameter and distance of biopsy pathway. Interventional radiologist-related rates of complications were not statistically different. CONCLUSIONS Technical success of percutaneous, transthoracic lung needle biopsies of pulmonary tumors is probably dependent on the interventional radiologist. In addition, lesion diameter and length of biopsy pathway are predictors of the rate of complications.
منابع مشابه
PERCUTANEOUS TRANSTHORACIC BIOPSY USING TRU-CUT NEEDLE
Biopsies of thoracic lesions guidance. 22 of the 1 12 lesions were mediastinal and 83 were pleuroparenchymal. A large-bore 14-gauge Tru-cut needle was used in all patients. Adequate specimens for histologic examination were obtained in 98%. The overall accuracy was 91 % with 9% false negative and no false positive diagnoses. Despite the large size of the needle, the total number of complic...
متن کاملLung Lesions Biopsy in Children by Computed Tomography (CT) Fluoroscopy Guided Versus Conventional CT Scan Guided
Abstract Background Computed tomography (CT)-guided biopsy of the lung is a well-established method of diagnosis. The aim of this study was to determine the success rate of fluoroscopic CT (FCT) and conventional CT (CCT) in needle navigation biopsies from the lung lesions. Materials and Methods A total of 78 patients were prospectively enrolled to receive CT-guided biopsy with (group I, n=2...
متن کاملCurrent role of computed tomography-guided transthoracic needle biopsy of metastatic lung lesions.
AIM As part of the Catania symposium on lung metastasectomy we reviewed our practice of computed tomography (CT)-guided percutaneous transthoracic needle biopsy of pulmonary metastatic lesions with particular emphasis on diagnostic accuracy and nature of complications lesions. MATERIALS & METHODS 25 patients with metastatic lesions of the lung have been evaluated between May 2010 and February...
متن کاملتعیین ارزش تشخیصی بیوپسی سوزنی ترانس توراسیک با راهنمایی سونوگرافی در تشخیص تودههای محیطی ریه
Normal 0 false false false EN-GB X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tstyle-rowband-size:0 mso-tstyle-colband-size:0 mso-style-noshow:yes mso-style-priority:99 mso-style-qformat:yes m...
متن کاملDiagnostic Accuracy of CT-Guided Transthoracic Needle Biopsy for Solitary Pulmonary Nodules
To evaluate the diagnostic accuracy of computed tomography (CT)-guided percutaneous lung biopsy for solitary pulmonary nodules. Three hundred and eleven patients (211 males and 100 females), with a mean age of 59.6 years (range, 19-87 years), who were diagnosed with solitary pulmonary nodules and underwent CT-guided percutaneous transthoracic needle biopsy between January 2008 and January 2014 ...
متن کامل