Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study.
نویسندگان
چکیده
BACKGROUND Successful hip reconstruction to restore the normal hip biomechanics requires precise placement of implants. Computer assisted navigation in total hip arthroplasty has been proposed to have the potential to help achieve a high accuracy in implant placement. The goal of the study was to evaluate the accuracy of an imageless computer navigation system on cadavers and to validate a non-invasive computed tomography method for post-operative determination of acetabular cup orientation. METHODS Total hip arthroplasty was performed on seven cadaver hips with the aid of an imageless computer navigation system. The achieved cup orientation were recorded using three methods, (1) intra-operatively using the imageless computer navigation system, (2) post-operatively with direct bone digitization and (3) with a computed tomography based three dimensional model interpreted by three raters. Measurement from the direct bone digitization was taken as the gold standard to evaluate the other two methods. The intra-rater and inter-rater consistency of the computer tomography-model method were assessed by Cronbach's alpha determination. FINDINGS Compared with the cup orientation obtained from the direct bone digitization, the average difference for anteversion and abduction were 3.3 (3.5) degrees (P=0.045) and 0.6 (3.7) degrees , respectively, for navigation reading. The average differences for computer tomography-model for three raters were 0.5 (2.1) degrees , 0.8 (1.5) degrees and 3.2 (3.3) degrees (P=0.043) for anteversion and 0.4 (1.6) degrees , 0.3 (1.6) degrees and 2.1 (2.7) degrees for abduction. The intra-rater consistency ranged from 0.626 for a novice rater to over 0.97 for experience raters. The inter-rater consistency (including novice and experienced raters) was over 0.90. INTERPRETATION While the values for cup orientation determined with imageless computer navigation were comparable to those from direct bone and implant digitization, the measurement for anteversion obtained was not as accurate as that for abduction. The proposed computer tomography-model method has an excellent intra-rater consistency for experienced raters, as well as an excellent overall inter-rater consistency. The study confirms that a non-invasive computed tomography based model analysis can be used in clinical practice as a valid method for post-operatively evaluating the orientation of the acetabular component.
منابع مشابه
Accuracy of Image-based Computer Assisted Surgery in Acetabular Cup Placement for Supine Two-incision Total Hip Arthroplasty
Introduction: Supine patient positioning in conjunction with twoincision minimally invasive surgery (MIS-2 incision) total hip arthroplasty (THA) increases difficulty of accurate and repeatable cup orientation in accordance with pre-operative planning. Investigators have suggested advantages of utilizing computer assisted orthopaedic surgery (CAOS) to successfully eliminate extreme outlying ace...
متن کاملImproving cup positioning using a mechanical navigation instrument.
BACKGROUND Although surgical navigation reduces the rate of malpositioned acetabular cups in total hip arthroplasty (THA), its use has not been widely adopted. As a result of our perceived need for simple and efficient methods of navigation, we developed a mechanical navigation device for acetabular cup orientation. QUESTIONS/PURPOSES We assessed accuracy of cup orientation (mean error of cup...
متن کاملComputer - Assisted Navigation for Acetabular Cup Placement : a Single Image Guiding System
Incorrect angular placement of the acetabular cup in total hip replacement induces femoral head dislocation, osteolysis, and liner wearing. Some computer-assisted navigation systems to aid acetabular cup placement have been developed in the past decade, but these are not used extensively due to their expense. In this study, a novel algorithm to determine the positions of data points in three-di...
متن کاملAccuracy of acetabular cup positioning using imageless navigation
BACKGROUND Correct placement of the acetabular cup is a crucial step in total hip replacement to achieve a satisfactory result and remains a challenge with free-hand techniques. Imageless navigation may provide a viable alternative to free-hand technique and improve placement significantly. The purpose of this project was to assess and validate intra-operative placement values for both inclinat...
متن کاملA Comparison of the Conventional (manual) and a Computer-assisted Navigation Method in Total Hip Arthroplasty (tha)
prosthesis model based on CT scans; A detailed acetabular cup is shown at bottom right; A coordinate system and anatomical frontal pelvic plane on the 3D model are shown at bottom left. ASISs are marked black, PTs are in green, and the points on the cup rim are in red. A COMPARISON OF THE CONVENTIONAL (MANUAL) AND A COMPUTER-ASSISTED NAVIGATION METHOD IN TOTAL HIP ARTHROPLASTY (THA) Wixson, R.L...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical biomechanics
دوره 23 8 شماره
صفحات -
تاریخ انتشار 2008