Three new low-osmolality contrast agents: a comparative study of patient discomfort.

نویسندگان

  • D C Smith
  • P Y Yahiku
  • M D Maloney
  • K L Hart
چکیده

Relative patient discomfort resulting from carotid injections of three new low-osmolality contrast agents was assessed in 78 patients. Omnipaque-300 (iohexol), Isovue-300 (iopamidol), and hexabrix (ioxaglate) were sequentially injected into both common carotid arteries of each patient. Patients were asked to rank the relative intensities of the three injections on each side. Mean patient rankings revealed that Hexabrix was preferred most often, Omnipaque-300 next, and Isovue-300 the least. The differences are statistically significant. We conclude that while patients usually tolerated all intracarotid low-osmolality contrast agents rather well, the agent preferred most often was Hexabrix.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of low- with high-osmolality contrast agents in cardiac angiography. Identification of criteria for selective use.

BACKGROUND Controversy exists as to whether low-osmolality radiographic contrast agents, which have less detrimental pharmacological effects but are considerably more expensive than high-osmolality agents, should be used universally or only for selected high-risk patients. METHODS AND RESULTS A randomized, double-blind study was used to compare the frequency and severity of adverse events in ...

متن کامل

Optimization of low-osmolality contrast media for cranial CT: a dose comparison of two contrast agents.

A prospective, randomized, double-blind comparative study of 200 patients was made to examine the image quality, safety, and costs of 100 ml of ioversol-320 (32 g iodine) and 150 ml of iohexol-300 (45 g iodine) in patients undergoing cranial CT. We found no statistically significant difference in image quality between the two low-osmolality, nonionic contrast agents at these doses. There was a ...

متن کامل

Patient Discomfort Associated with the Use of Intra-arterial Iodinated Contrast Media: A Meta-Analysis of Comparative Randomized Controlled Trials

BACKGROUND Discomfort characterized by pain and warmth are common adverse effects associated with the use of intra-arterial iodinated contrast media (CM). The objective of this review was to pool patient-reported outcomes available from head-to-head randomized controlled trials (RCTs) and to compare the discomfort rates associated with iso-osmolar contrast media (IOCM; i.e., iodixanol) to those...

متن کامل

A Comparison of Low- With High-Osmolalit Contrast Agents in Cardiac Angiography Identification of Criteria for Selective Use

Background Controversy exists as to whether low-osmolality radiographic contrast agents, which have less detrimental pharmacological effects but are considerably more expensive than high-osmolality agents, should be used universally or only for selected high-risk patients. Methods and Resuls A randomized, double-blind study was used to compare the frequency and severity of adverse events in 224...

متن کامل

Cost-effectiveness of unenhanced MR imaging vs contrast-enhanced CT of the abdomen or pelvis.

OBJECTIVE The purpose of this study was to compare the cost of unenhanced MR imaging with that of CT with high- or low-osmolality contrast agents for abdominal or pelvic imaging in patients at risk for nephrotoxic effects induced by contrast material. MATERIALS AND METHODS Using decision analysis, we evaluated direct medical care costs associated with the use of CT with high- or low-osmolalit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 1988