Image Quality and Radiation Dose of Lower Extremity CT Angiography Using 70 kVp, High Pitch Acquisition and Sinogram-Affirmed Iterative Reconstruction
نویسندگان
چکیده
OBJECTIVES The purpose of this study was to assess image quality and radiation dose of lower extremity CT angiography (CTA) with 70 kVp, high pitch acquisition and sinogram-affirmed iterative reconstruction (SAFIRE). METHODS Lower extremity CTAs were performed on 44 patients: 22 patients were examined using protocol A (120 kVp, pitch of 0.85 and 120 ml of contrast agent on a first-generation dual-source CT) (120 kVp group) and 22 patients were evaluated with protocol B (70 kVp, pitch of 2.2 and 80 ml of contrast agent on a second-generation dual-source CT) (70 kVp group). Images from the 120 kVp group were reconstructed with filtered back projection (FBP) and images from the 70 kVp group with SAFIRE. The attenuation, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Two radiologists subjectively assessed image quality of lower extremity arteries, plantar arterial enhancement and venous contamination of all patients. Radiation dose was compared between the two groups. RESULTS Higher mean intravascular attenuation was obtained in the 70 kVp group (70 vs. 120 kVp group, 555.4 ± 83.4 HU vs. 300.9 ± 81.4 HU, P<0.001), as well as image noise (20.0 ± 2.8 HU vs. 17.5 ± 3.2 HU, P = 0.010), SNR (32.0 ± 7.0 vs. 19.1 ± 6.9, P<0.001) and CNR (28.1 ± 6.6 vs 15.9 ± 6.3, P<0.001). No difference in subjective image quality and plantar arterial enhancement was found between 120 kVp group and 70 kVp group (all P>0.05). The venous contamination score was 1.5 ± 0.8 for 120 kVp group while no venous contamination was found in 70 kVp group. The inter-observer agreement was moderate to good for both groups (0.515∼1, P<0.001). The effective dose was lower in 70 kVp group (0.3 ± 0.1 mSv) than in 120 kVp group (1.6 ± 0.7 mSv)(P<0.001). CONCLUSIONS Lower extremity CTA using 70 kVp, high pitch acquisition and SAFIRE, except increasing imaging noise, allows for lower radiation dose and contrast material volume without compromising image quality.
منابع مشابه
Low-Dose High-Pitch CT Angiography of the Supraaortic Arteries Using Sinogram-Affirmed Iterative Reconstruction
OBJECTIVE To prospectively evaluate image quality and radiation dose using a low-dose computed tomography angiography protocol and iterative image reconstruction for high-pitch dual-source CT-angiography (DSCTA) of the supraaortic arteries. MATERIAL AND METHODS DSCTA was performed in 42 patients, using either 120 kVp tube voltage, 120 mAS tube current, 2.4 pitch and filtered back projection, ...
متن کاملImpact of Sinogram Affirmed Iterative Reconstruction (SAFIRE) Algorithm on Image Quality with 70 kVp-Tube-Voltage Dual-Source CT Angiography in Children with Congenital Heart Disease
PURPOSE To compare the image quality and diagnostic accuracy between sinogram affirmed iterative reconstruction (SAFIRE) algorithm and filtered back projection (FBP) reconstruction algorithm at 70 kVp-tube-voltage DSCT angiography in children with congenital heart disease (CHD). MATERIALS AND METHODS Twenty-eight patients (mean age: 13 months; range: 2-48 months; male: 16; female: 12; mean we...
متن کاملIndirect CT Venography at 80 kVp with Sinogram-Affirmed Iterative Reconstruction Compared to 120 kVp with Filtered Back Projection: Assessment of Image Quality and Radiation Dose
OBJECTIVE To evaluate the image quality and radiation dose of indirect computed tomographic venography (CTV) using 80 kVp with sinogram-affirmed iterative reconstruction (SAFIRE) and 120 kVp with filtered back projection (FBP). MATERIALS AND METHODS This retrospective study was approved by our institution and informed consent was waived. Sixty-one consecutive patients (M: F = 27: 34, mean age...
متن کاملProspective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose
Background: Prospectively electrocardiography (ECG)-triggered high-pitch spiral coronary computed tomography angiography (CCTA) is a unique scan mode for dual-source CT (DSCT). Our reports aim to compare image quality and radiation dose of CCTA using high-pitch spiral or sequential acquisition mode in patients with low and stable heart rates. Materials and Methods: Patients with low and stable ...
متن کاملUltralow-dose chest computed tomography for pulmonary nodule detection: first performance evaluation of single energy scanning with spectral shaping.
PURPOSE The purpose of this study was to evaluate the image quality and sensitivity of ultralow radiation dose single-energy computed tomography (CT) with tin filtration for spectral shaping and iterative reconstructions for the detection of pulmonary nodules in a phantom setting. METHODS Single-energy CT was performed using third-generation dual-source CT (SOMATOM Force; 2 × 192 slices) at 7...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2014