AIMS To evaluate the mid-term efficacy and safety of the GTS-400-iStent combined with phacoemulsification in patients with cataract and open-angle glaucoma (OAG) or ocular hypertension (OHT). METHODS Prospective, non-comparative, uncontrolled, interventional case series study. Subjects underwent phacoemulsification and two GTS-400 implantation. Efficacy outcomes: intraocular pressure (IOP) and antiglaucoma medications. Safety outcomes: complications, best-corrected visual acuity and endothelial cell count (ECC). Follow-up was 1 year. RESULTS 20 patients were enrolled (mean age: 75.1 ± 8.6 years). Mean medicated baseline IOP was 19.95 ± 3.71 mm Hg and 26 ± 3.11 mm Hg without medication. Mean final IOP was 16.75 ± 2.24, determining a final IOP decrease of 35.68% (9.42 ± 3 mm Hg; p<0.001), from baseline washout IOP. Mean number of medications fell from 1.3 ± 0.66 to 0.3 ± 0.57 (P<0.001). 75% of patients were off medications at one year. Mean ECC decreased from 2289.64 ± 393.5 cells/mm(2) to 1986.95 ± 520.58 cells/mm(2). CONCLUSIONS Combined cataract surgery with implantation of GTS-400-iStent seems to be an effective and safe procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Glaukos iStent inject® Trabecular Micro-Bypass Implantation Associated with Cataract Surgery in Patients with Coexisting Cataract and Open-Angle Glaucoma or Ocular Hypertension: A Long-Term Study

Purpose. To evaluate the long-term efficacy and safety of the iStent inject device (Glaukos Corporation, Laguna Hills, CA) combined with phacoemulsification in patients with coexistent cataract and open-angle glaucoma or ocular hypertension (OHT). Methods. A prospective, uncontrolled, nonrandomized, interventional case series study was conducted in patients with both mild or moderate open-angle...

متن کامل

Effects of Glaukos® Trabecular Stent in the Treatment of Glaucoma

Micro-invasive glaucoma surgery (MIGS) is gaining interest in very recent years, due to a better safety profile and good tensional results, often associated to cataract surgery. Glaukos iStent® is the only FDA-approved device for micro-invasive glaucoma surgery. It connects the anterior chamber to Schlemm ́s canal by bypassing the trabecular meshwork, increasing the outflow facility. The Glaukos...

متن کامل

Micro-Bypass Implantation for Primary Open-Angle Glaucoma Combined with Phacoemulsification: 4-Year Follow-Up

Purpose. To report the long-term follow-up results in patients with cataract and primary open-angle glaucoma (POAG) randomly assigned to cataract surgery combined with micro-bypass stent implantation or phacoemulsification alone. Methods. 36 subjects with cataract and POAG were randomized in a 1 : 2 ratio to either iStent implantation and cataract surgery (combined group) or cataract surgery al...

متن کامل

iStent trabecular micro-bypass stent for open-angle glaucoma

Trabecular micro-bypass stents, commonly known as iStents, are micro-invasive glaucoma surgery (MIGS) devices used to treat open-angle glaucoma. Like other MIGS procedures that enhance trabecular outflow, the iStent lowers intraocular pressure (IOP) by creating a direct channel between the anterior chamber and Schlemm's canal. iStents are typically implanted at the time of phacoemulsification f...

متن کامل

iStent with Phacoemulsification versus Phacoemulsification Alone for Patients with Glaucoma and Cataract: A Meta-Analysis

BACKGROUND Minimally invasive glaucoma surgeries (MIGS) have attracted significant attention, as they have been reported to lower intra-ocular pressure (IOP) and have an excellent safety profile. The iStent is an example of a minimally invasive glaucoma device that has received particular attention due to its early and wide spread utilization. There is a growing body of evidence supporting its ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 97 10  شماره 

صفحات  -

تاریخ انتشار 2013