Correlation of interference screw insertion torque with depth of placement in the tibial tunnel using a quadrupled semitendinosus-gracilis graft in anterior cruciate ligament reconstruction.

نویسندگان

  • Barry B Phillips
  • E Lyle Cain
  • Jeffrey A Dlabach
  • Frederick M Azar
چکیده

PURPOSE To evaluate the insertion torque of a soft-tissue interference screw in relation to depth of insertion into the tibial tunnel when used for fixation of a quadrupled semitendinosus-gracilis autograft in anterior cruciate ligament reconstruction. TYPE OF STUDY Biomechanical cadaver study. METHODS Ten quadrupled semitendinosus-gracilis grafts were harvested from fresh-frozen cadaver knees and fixed in donor proximal tibias using 10-mm bioabsorbable interference screws (Arthrex, Naples, FL). A cannulated torque screwdriver was used to measure screw insertion torque at 3 depths in the tibial tunnel: the outer cortex (distal third), the articular surface (proximal third), and between these 2 points (middle third). RESULTS The mean insertion torques for the distal third, middle third, and proximal third were 8.7, 4.7, and 4.3 in/lb, respectively. The insertion torque was significantly higher at the outer cortex (distal third) than the middle third and proximal third (joint line of the tibial tunnel) ( P < .05). CONCLUSIONS Our results indicate a correlation between insertion torque and depth of placement of bioabsorbable interference screws used for fixation of a semitendinosus-gracilis graft. Lower insertion torque at the articular surface, resulting in lower peak load or pullout strength, may outweigh the proposed benefits of joint-line fixation of a semitendinosus-gracilis graft used for anterior cruciate ligament reconstruction. CLINICAL RELEVANCE Studies have suggested that anatomic proximal fixation of ACL grafts in the tibial tunnel produces stability similar to intact knees. The results of our study indicate that lower insertion torque at the articular surface results in lower peak load and pullout strength of the graft, which may outweigh the proposed benefits of joint-line fixation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

Anatomic double-bundle posterior cruciate ligament reconstruction using hamstring tendons.

Recent biomechanical studies have shown that an anatomic double-bundle posterior cruciate ligament (PCL) reconstruction is superior in restoring normal knee laxity compared with the conventional single-bundle isometric reconstruction. We describe a modification of an endoscopic PCL reconstruction technique using a double-bundle Y-shaped hamstring tendon graft. A double- or triple-bundle semiten...

متن کامل

Comparison between the Results Achieved in Anterior Cruciate Ligament Reconstruction with Two Kinds of Autologous Grafts: Patellar Tendon versus Semitendinous and Gracilis

OBJECTIVE this study aims to compare the arthrometric and isokinetic examination results from two types of autologous grafts: the central third of the patellar ligament and a graft formed by the tendons of the semitendinosus and gracilis muscles, within the same rehabilitation protocol, six months after the surgery. METHODS the results from examinations carried out on 63 patients were analyze...

متن کامل

[The effect of anterior or posterior tibial tunnel placement of a soft tissue graft with a soft tissue interference screw on fixation biomechanics].

OBJECTIVES We investigated the biomechanical characteristics of anterior or posterior tibial tunnel placement of the soft tissue graft with a soft tissue interference screw in anterior cruciate ligament (ACL) reconstruction. METHODS Twelve bovine tibiae and digital extensor tendons were divided into two homogeneously equal groups after they were stripped of all soft tissues. Tibial tunnels we...

متن کامل

Bone tunnel enlargement on anterior cruciate ligament reconstruction

OBJECTIVE To assess the presence of tibial bone tunnel enlargement after surgical reconstruction of the anterior cruciate ligament using quadruple graft of the flexor tendons and correlate the functional results in their presence. METHODS The studied lasted six months and included 25 patients, with ages ranging from 18 to 43 years old. Assessment was based on radiographs taken immediately pos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association

دوره 20 10  شماره 

صفحات  -

تاریخ انتشار 2004