Determination of proteins using the p-acetylchlorophosphonazo-barium(II) complex as a spectroprobe.
نویسندگان
چکیده
A novel spectrophotometric method has been developed for the determination of proteins using the p-acetychlorophosphonazo (CPA-pA)-barium(II) complex as a spectroprobe. In the pH range of 2.0-2.8, the absorbance of the CPA-pA-barium(II) complex at 649 nm is greatly decreased by protein. The absorbance decrease is in proportion to the concentration of protein in the range of 0-20 mg/L. The apparent molar absorptivities are 1.56 x 10(6), 1.70 x 10(6) and 6.04 x 10(5) L mol(-1) cm(-1) for bovine serum albumin (BSA), human serum albumin (HAS) and ovalbumin (OVA), respectively. The method is reproducible and simple, and has been used to determine total protein in human sera. The results are in agreement with those obtained by the pyrocatechol violet (PV)-Mo(VI) method, with relative standard deviations of 2.5-3.5% (n=6).
منابع مشابه
Solvent extraction, spectrophotometric determination of copper (II) from environmental samples using o-methylphenyl thiourea as a novel reagent
A simple and rapid method has been developed for solvent extraction and spectrophotometric determination of copper (II) using o-methylphenyl thiourea (OMPT) as a sensitive reagent. The basis of proposed method is formation of copper (II)-OMPT complex. Copper (II) was extracted with 0.020 mol L-1 OMPT in chloroform from aqueous solution in 0.075 mol L-1 potassium iodate. The absorbance of comple...
متن کاملVoltammetric determination of cysteine at a carbon paste electrode modified with Cu(II)-salen complex
The electrochemical behavior of a modified carbon paste electrode (MCPE) with N,N′ethylenbis(salicylideneiminato)copper(II) complex ([Cu(II)-Salen]) was investigated as a newsensor for cystein. The Britton-Robinson buffer with pH 5, 10% modifier in electrode, potentialscanning rate of 20 mVs-1 and puls height of 50 mV were used as the optimum condition for thedetermination of cysteine using car...
متن کاملExtraction of Traces of Copper as Tetra-Butylammonium Tetrathiocyanato Copper (II) and Its Spectrophotometric Determination Using Eriochrome Black T
An extraction-spectrophotometric method for the determination of traces of copper (II) is described. The method is based on the quantitative extraction of copper as tetrabutylammonium tetrathiocyanato copper (II) into methyl isobutyl ketone, followed by spectrophotometric determination, using eriochrome black T as a metallochromic indicator. The red-violet mixed complex of copper absorbs at...
متن کاملTrace determination and separation of tin (II) by floatation-spectrophotometric using kalmagyte and CTAB
ABSTRACTA novel floatation-spectrophotometric extraction method was developed for the recovery of tin (II) from aqueous samples prior to determination by UV spectrophotometric detection. The method is based on the formation of a complex between tin (II) and kalmagyte in pH=8. The complex is floated in the interface of n-hexane and aqueous phases. After removing the aqueous phase, the floated pa...
متن کاملSynthesis, Characterization and Crystal Structure Determination of Copper (II) Complexes with 2,2′-Dimethyl-4,4′-bithiazole
Copper(II) complex [Cu(dmbt)2(H2O)](ClO4)2 (1) was prepared from the reaction of copper(II) perchlorate hexahydrate with 2,2'-dimethyl-4,4'-bithiazole (dmbt) ligand in methanol at ambient temperature. The complex was quantitatively and qualitatively characterized by elemental analysis, absorption and infrared spectrometries. Complex [Cu(DMSO)5](ClO4)2 (2) was also synt...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 19 8 شماره
صفحات -
تاریخ انتشار 2003