An audible indication of exhalation increases delivered tidal volume during bag valve mask ventilation of a patient simulator.

نویسندگان

  • Samsun Lampotang
  • D E Lizdas
  • N Gravenstein
  • S Robicsek
چکیده

Self-inflating manual resuscitators (SIMRs) can mislead caregivers because the bag, unlike a Mapleson-type device, reinflates even without patient exhalation. We added a whistle as an audible indicator to the exhalation port of a SIMR. In randomized order, each participant provided two sets of breaths via mask ventilation with a SIMR, one with and one without audible feedback, to a Human Patient Simulator modified to log lung volume changes. The last three breaths in each set were used to compare average tidal volume (Vt) under both conditions. Eighty-seven advanced cardiac life support trainees (54 males, 33 females) with clinical experience averaging 6.4 +/- 9.4 yr were recruited. Average Vt delivered with the standard SIMR was 486 +/- 166 mL and 624 +/- 96 mL with the modified SIMR. Average Vt delivered by a modified SIMR was significantly larger by 40% when it followed standard SIMR use and 19% when using the modified SIMR first. Use of a SIMR with an audible indicator of exhalation significantly (P < 0.001) increased mask ventilation of a patient simulator, suggesting that mask ventilation of a patient with a SIMR may also be increased by objective, real-time feedback of exhaled Vt.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of bag-valve-mask hand-sealing techniques in a simulated model.

STUDY OBJECTIVE Bag-valve-mask ventilation remains an essential component of airway management. Rescuers continue to use both traditional 1- or 2-handed mask-face sealing techniques, as well as a newer modified 2-handed technique. We compare the efficacy of 1-handed, 2-handed, and modified 2-handed bag-valve-mask technique. METHODS In this prospective, crossover study, health care providers p...

متن کامل

Comparison of an oxygen-powered flow-limited resuscitator to manual ventilation with an adult 1,000-mL self-inflating bag.

BACKGROUND Positive-pressure ventilation of patients with unprotected airways during cardiopulmonary resuscitation can cause gastric dilation. OBJECTIVE Determine if there is a significant difference in volume delivered to lungs and stomach while using an adult 1,000-mL disposable bag-valve-mask (BVM) device and the oxygen-powered, flow-limited Oxylator EMX resuscitator. METHODS We used a b...

متن کامل

An evaluation of bag-valve-mask ventilation using an ergonomically designed facemask among novice users: a simulation-based pilot study.

PURPOSE We sought to compare the ability of novice operators to provide artificial ventilation using a standard facemask and a new ergonomically designed facemask. Whether or not proper technique was used was also assessed. METHODS Thirty-two allied-health students used both masks in random crossover fashion to ventilate an airway trainer. Breaths were delivered by a mechanical ventilator and...

متن کامل

Emergency airway management by non-anaesthesia house officers--a comparison of three strategies.

OBJECTIVES The purpose of this study was to determine effects of different airway devices and tidal volumes on lung ventilation and gastric inflation in an unprotected airway. METHODS Thirty one non-anaesthesia house officers volunteered for the study, and ventilated a bench model simulating an unintubated respiratory arrest patient with bag-valve-facemask, laryngeal mask airway, and combitub...

متن کامل

Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks.

BACKGROUND The key to successful neonatal resuscitation is effective ventilation. Little evidence exists to guide clinicians in their choice of manual ventilation device or face mask. The expiratory tidal volume measured at the mask (V(TE(mask))) is a good estimate of the tidal volume delivered during simulated neonatal resuscitation. AIM To compare the efficacy of (a) the Laerdal infant resu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 102 1  شماره 

صفحات  -

تاریخ انتشار 2006