This 55-year-old female had a chest X-ray during a follow-up visit for the management of her breast cancer. The chest X-ray demonstrated an embolized venous catheter superimposed upon the mediastinum. It was determined that the catheter of the patient's arm port had fractured and embolized to the pulmonary circulation. The catheter was retrieved, in the interventional radiology suite, under fluoroscopic guidance. The patient suffered no ill effects. Subsequently, one day later, the old vein port was removed and a new arm port and associated catheter were implanted to facilitate the delivery of the patient's ongoing chemotherapy.
منابع مشابه
Percutaneous retrieval of an intracardiac central venous port fragment using snare with triple loops
Peripherally inserted venous ports fracture with embolization in patients who received chemotherapy is a serious and rare complication, and few cases have been reported in children. We report a successful endovascular technique using a snare for retrieving broken peripherally inserted venous ports in a child for chemotherapy. Catheter fragments may cause complications such as cardiac perforatio...
متن کاملAn unusual cause of ventricular tachycardia: Port-A-Cath fracture and embolization into the pulmonary artery.
We describe the case of a patient with a previously placed Port-A-Cath who was admitted to hospital for new onset of non-flushing catheter and palpitations with ventricular tachycardia. A chest X-ray and a linogram showed a Port-A-Cath fracture and distal embolization into the right ventricle resulting in ventricular tachycardia. The catheter was removed percutaneously using a Goose Neck snare ...
متن کاملCentral venous catheter fracture.
665 The Journal of the American Osteopathic Association August 2014 | Vol 114 | No. 8 An 18-year-old woman presented with a 1-day history of edema and erythema associated with a port central venous access device of the anterior left chest wall. The patient reported difficulty with catheter flushing for 2 days. Medical history included severe gastroparesis requiring placement of the catheter 2 m...
متن کاملPort catheter fracture and migration in Internal Jugular Vein
BACKGROUND Central venous access devices for chemotherapy are being used extensively in patients with cancer. Spontaneous fracture and migration of the catheter is uncommon. We present the uncommon occurrence of a fracture and spontaneous migration of the fragment into the internal jugular vein as a delayed complication of a central venous access catheter implanted for chemotherapy administrati...
متن کاملA knotted problem.
Arch Dis Child January 2011 Vol 96 No 1 An 8-year-old boy with cystic fi brosis was planned for a course of home intravenous antibiotics. A peripherally inserted central catheter (PICC) was inserted from his left wrist on the third attempt. By the third day, he had developed a swollen red forearm. Clinically, a small non-tender nodule was palpable 1 cm proximal to a healthy insertion site. The ...