Effect of mobility devices on orientation sensors that contain magnetometers.
نویسندگان
چکیده
Orientation sensors containing magnetometers use the earth's magnetic field as a reference. Ferromagnetic objects may distort this magnetic field, leading to inaccurate orientation output. We explored the viability of these orientation sensors for motion analysis in an assistive mobility device rehabilitative setting. We attached two MTx orientation sensors (XSens; Enschade, the Netherlands), connected to the XBus Master data collection unit (XSens), to a plastic frame such that the relative angle between sensors was constant. We then moved a series of mobility devices in proximity to the plastic frame: two knee-ankle-foot orthoses (aluminum, stainless steel), one ankle-foot orthosis, two transtibial prostheses (exoskeletal, endoskeletal), two walkers (standard, Challenger Low Wide [Evolution Technologies; Port Coquitlam, Canada]), and two wheelchairs (Tango [OrthoFab; Quebec City, Canada], GTi [Quickie; Phoenix, Arizona]). For each mobility device, we calculated the average difference in relative angle between the baseline and peak angles for each of five trials. Errors ranged from less than 0.10 to 35.29 degrees, depending on the mobility device and frame positioning near the device. This demonstrated the large errors that can occur when magnetometer-based orientation sensors with mobility devices are used. While strategic orientation sensor placement on some mobility devices can minimize these errors to an acceptable level, testing protocols should be implemented to verify orientation sensor accuracy for these applications.
منابع مشابه
Multi-Magnetometer Based Perturbation Mitigation for Indoor Orientation Estimation
Determining orientation with respect to a known reference plays an important role in almost all modes of navigation. As the sensors required for measuring magnetic field have found their way into portable navigation devices, researchers have started investigating their application to orientation estimation in different environments. Nevertheless, the success of these sensors for orientation est...
متن کاملSwarm Optimization-Based Magnetometer Calibration for Personal Handheld Devices
Inertial Navigation Systems (INS) consist of accelerometers, gyroscopes and a processor that generates position and orientation solutions by integrating the specific forces and rotation rates. In addition to the accelerometers and gyroscopes, magnetometers can be used to derive the user heading based on Earth’s magnetic field. Unfortunately, the measurements of the magnetic field obtained with ...
متن کاملTracking the kinematics of caudal-oscillatory swimming: a comparison of two on-animal sensing methods.
Studies of locomotion kinematics require high-resolution information about body movements and the specific acceleration (SA) that these generate. On-animal accelerometers measure both orientation and SA but an additional orientation sensor is needed to accurately separate these. Although gyroscopes can perform this function, their power consumption, drift and complex data processing make them u...
متن کاملInteraction: an Interactive Knee Angle Measurement System for at Home Physical Therapy
INTRODUCTION In the United States alone, 600,000 total knee replacements are performed each year [4]. Rehabilitation from this type of procedure is often prescribed to be performed by the patients at their own home [1]. The main problem with at home physical therapy is that it is hard for the therapists to monitor how their patients are performing the prescribed exercises. The patients could pe...
متن کاملMagnetic Calibration of Three-Axis Strapdown Magnetometers for Applications in Mems Attitude-Heading Reference Systems
In a strapdown magnetic compass, heading angle is estimated using the Earth's magnetic field measured by Three-Axis Magnetometers (TAM). However, due to several inevitable errors in the magnetic system, such as sensitivity errors, non-orthogonal and misalignment errors, hard iron and soft iron errors, measurement noises and local magnetic fields, there are large error between the magnetometers'...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of rehabilitation research and development
دوره 46 7 شماره
صفحات -
تاریخ انتشار 2009