High-throughput flow cytometry data normalization for clinical trials.

نویسندگان

  • Greg Finak
  • Wenxin Jiang
  • Kevin Krouse
  • Chungwen Wei
  • Ignacio Sanz
  • Deborah Phippard
  • Adam Asare
  • Stephen C De Rosa
  • Steve Self
  • Raphael Gottardo
چکیده

Flow cytometry datasets from clinical trials generate very large datasets and are usually highly standardized, focusing on endpoints that are well defined apriori. Staining variability of individual makers is not uncommon and complicates manual gating, requiring the analyst to adapt gates for each sample, which is unwieldy for large datasets. It can lead to unreliable measurements, especially if a template-gating approach is used without further correction to the gates. In this article, a computational framework is presented for normalizing the fluorescence intensity of multiple markers in specific cell populations across samples that is suitable for high-throughput processing of large clinical trial datasets. Previous approaches to normalization have been global and applied to all cells or data with debris removed. They provided no mechanism to handle specific cell subsets. This approach integrates tightly with the gating process so that normalization is performed during gating and is local to the specific cell subsets exhibiting variability. This improves peak alignment and the performance of the algorithm. The performance of this algorithm is demonstrated on two clinical trial datasets from the HIV Vaccine Trials Network (HVTN) and the Immune Tolerance Network (ITN). In the ITN data set we show that local normalization combined with template gating can account for sample-to-sample variability as effectively as manual gating. In the HVTN dataset, it is shown that local normalization mitigates false-positive vaccine response calls in an intracellular cytokine staining assay. In both datasets, local normalization performs better than global normalization. The normalization framework allows the use of template gates even in the presence of sample-to-sample staining variability, mitigates the subjectivity and bias of manual gating, and decreases the time necessary to analyze large datasets.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Per-channel basis normalization methods for flow cytometry data.

Between-sample variation in high-throughput flow cytometry data poses a significant challenge for analysis of large-scale data sets, such as those derived from multicenter clinical trials. It is often hard to match biologically relevant cell populations across samples because of technical variation in sample acquisition and instrumentation differences. Thus, normalization of data is a critical ...

متن کامل

Comparison of plaque- and flow cytometry-based methods for measuring dengue virus neutralization.

As dengue vaccines enter clinical trials, there is a need for rapid and quantitative assays to measure neutralization. We have developed flow-based neutralization assays which generated results similar to those generated by the established, plaque reduction neutralization test. The flow assays are an improvement, as they use human cells and allow for high-throughput screening.

متن کامل

P-95: Flow Cytometry Analysis of Bovine Semen:A Qualitative Study

Background: Although AI practices have been introduced little over 60 years, the success rate remains relatively low. This might be due to the exclusive selection of semen based on motility analysis. Recent advancement in sperm sexing using flow cytometry with an increased throughput from next generation cell sorters, made use of this technology in studding sperm qualitative aspects other than ...

متن کامل

Development and optimization of high-throughput methods to measure Plasmodium falciparum-specific growth inhibitory antibodies.

Antibodies that inhibit replication of Plasmodium falciparum in erythrocytes are thought to be important both in acquired immunity to malaria and as mediators of immunity generated by candidate blood-stage vaccines. However, several constraints have limited the study of these functional antibodies in population studies and vaccine trials. We report the development and optimization of high-throu...

متن کامل

Microfluidic Impedance Flow Cytometry Enabling High-Throughput Single-Cell Electrical Property Characterization

This article reviews recent developments in microfluidic impedance flow cytometry for high-throughput electrical property characterization of single cells. Four major perspectives of microfluidic impedance flow cytometry for single-cell characterization are included in this review: (1) early developments of microfluidic impedance flow cytometry for single-cell electrical property characterizati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cytometry. Part A : the journal of the International Society for Analytical Cytology

دوره 85 3  شماره 

صفحات  -

تاریخ انتشار 2014