A Dosimetric Comparison of Double Arc Volumetric Modulated Arc Therapy with Large Field Intensity Modulated Radiation Therapy for Head and Neck Cancer

نویسندگان

  • Jayapalan Krishnan
  • Suresh Rao
  • Sanath Hegde
  • Jayarama Shetty
چکیده

Background: This Study Evaluate two state of Art techniques, Rapid Arc and large-field sliding window IMRT in terms of dosimetric end points and delivery time for head and neck cancer. Materials and Methods: 22 patients with head and neck cancer were selected for a planning comparative study. All patients went to CT-simulation in supine position. PTVs were delineated for two dose level of prescription 70 Gy to the boost-PTV70Gy and 54 Gy to the elective-PTV54Gy in 35 equal fraction/day. Simultaneous Integrated Boost (SIB) technique plan was generated for all patients and optimized with both techniques, Rapid Arc and IMRT with similar planning objectives. Dose of all plans of both techniques were calculated for 6MV photon using AAA implemented in Eclipse treatment planning system (10.0.39) with calculating grid size of 2.5 mm. Results: Comparison of Rapid Arc and IMRT plans in every patient showed significantly higher conformity index (CI95%) (p = 0.021) and sparing of the all OARs with Rapid Arc. The average homogeneity Index (HI95%) of lower prescribed dose target PTV54Gy which is in proximity to Higher dose prescribed target PTV70Gy was improved significantly with rapid Arc (p = 0.0001). D1% of spinal cord dose reduced significantly (p = 0.047) with Rapid Arc and the average mean dose of both left-parotid (21.26 ± 8.5 Gy), right-parotid (22.37 ± 7.44 Gy) were received lesser than with IMRT (22.78 ± 11.2 Gy and 24.1 ± 7.96 Gy) respectively. A significantly less monitor unit (MU) was required to deliver the plan (p < 0.00001) with significantly lesser treatment time (p < 0.00001). Conclusion: Rapid Arc technique was superior to IMRT in sparing the OARs without compromising target coverage and delivered the plan with lesser monitor unit and treatment time. Corresponding author.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

Comparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison

Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI). Material and Methods: Planning data of 26 high grade glioma (HGG) patients were used. Prescrib...

متن کامل

Dose Distribution Analysis of Rapid Arc and Intensity Modulated Radiotherapy Plan in Head and Neck Cancer

Introduction: Globally, intensity-modulated radiation therapy (IMRT) is considered as highly precise and accurate method of radiotherapy planning. This technique amplifies spatial dose distribution conformity by modulating the intensity of radiation beams in each sub-volume. Additionally, it can reduces the dose to surrounding critical organs and deliver the planned dose to targets with the nom...

متن کامل

Validation of the relative insensitivity of volumetric-modulated arc therapy (VMAT) plan quality to gantry space resolution

Volumetric-modulated arc therapy (VMAT) is an efficient form of radiotherapy used to deliver intensity-modulated radiotherapy beams. The aim of this study was to investigate the relative insensitivity of VMAT plan quality to gantry angle spacing (GS). Most previous VMAT planning and dosimetric work for GS resolution has been conducted for single arc VMAT. In this work, a quantitative comparison...

متن کامل

Using overlap volume histogram and IMRT plan data to guide and automate VMAT planning: a head-and-neck case study.

PURPOSE To investigate whether an overlap volume histogram (OVH)-driven planning application using an intensity-modulated radiation therapy (IMRT) database can guide and automate volumetric-modulated arc therapy (VMAT) planning for head-and-neck cancer. METHODS Based on comparable head-and-neck dosimetric results between planner-generated VMAT and IMRT plans, an inhouse developed, OVH-driven ...

متن کامل

Multi-institutional comparison of volumetric modulated arc therapy vs. intensity-modulated radiation therapy for head-and-neck cancer: a planning study

BACKGROUND Compared to static beam Intensity-Modulated Radiation Therapy (IMRT), the main advantage of Volumetric Modulated Arc Therapy (VMAT) is a shortened delivery time, which leads to improved patient comfort and possibly smaller intra-fraction movements. This study aims at a treatment planner-independent comparison of radiotherapy treatment planning of IMRT and VMAT for head-and-neck cance...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015