Simultaneous spin-echo refocusing.

نویسندگان

  • Matthias Günther
  • David A Feinberg
چکیده

A new approach to spin-echo imaging is presented in which the 180 degrees RF pulse refocuses two or more spin-echoes at different positions in the readout period. When simultaneous echo refocusing (SER) is implemented using multiple 180 degrees pulses, an undesirable mixing of stimulated echoes and primary echoes from different slices can occur. A novel periodic gradient spoiler scheme eliminates this potential source of artifacts without spoiling the correctly timed stimulated echoes, which, similar to RARE (TSE) sequences, add coherently to the primary echoes. Comparisons show equivalent artifact elimination using phase cycling, periodic spoiling, and a previously developed spoiling scheme for non-Carr-Purcell-Meiboom-Gill sequences. A comparison of head images at 1.5 T acquired with SER-TSE and conventional TSE T1-weighted sequences show no degradation in image quality nor SNR. T2-weighted imaging is not achievable with the current implementation, but possible solutions are proposed. The proposed technique might prove especially beneficial at higher field strengths, where the reduced number of refocusing pulses for multislice SER-TSE decreases RF power deposition. SER spin-echo imaging offers an approach that is very different from low flip angle imaging to mitigate RF heating limitations in high-field clinical imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Echo Refocusing EPI (SER-EPI) using Spin Echoes

Fig. 1: General scheme for spin echo based SER-EPI sequence: The standard SER-scheme is extended not only by the refocusing 180 RF-pulse but also by a gradient pulse in phase-encoding direction. This gradient prephasing pulse aligns the gradient echo with the spin echo of the first excitation pulse s1. Fig.2: k-space data of spin-echo based SER-EPI sequence: Phase-encode direction is top to bot...

متن کامل

Multiplex RARE Dixon: a novel multislice RARE sequence applied to simultaneous slice fat-water Dixon imaging

Introduction Multislice excitation methods have been widely used to increase efficiency in volume coverage. In the simultaneous spin-echo refocusing sequence (SER) [1], two or more slices are excited simultaneously and refocused with a train of 180° pulses which act simultaneously on both slices. However, the SER sequence does not fulfil CPMG conditions, and requires special spoiler gradients t...

متن کامل

Fast SE/TSE/RARE, refocusing with low flip angle pulses

1 Introduction The spin echo is a fundamental principle (1) that can be used for magnetic resonance imaging. Spin echo techniques are characterized by at least two rf-pulses. The first rf-pulse acts as an excitation pulse that converts longitudinal magnetization into transverse magnetization, and a second rf-pulse after TE/2 is used as a refocusing pulse that (partially) inverts the accumulated...

متن کامل

Designing RF Refocusing Pulses for Parallel Transmit Spin Echo Sequences

INTRODUCTION Parallel transmission of RF pulses [1, 2] has shown great potential in B1 inhomogeneity correction at high fields [3]. Most of the existing applications of parallel transmission, however, have been restricted to only gradient echo due to lack of systematic design of parallel transmit refocusing pulses. The difficulty of designing such pulses lies in that 1) the large flip angle nat...

متن کامل

Effect of Low Refocusing Angle in T1-Weighted Spin Echo and Fast Spin Echo MRI on Low-Contrast Detectability: A Comparative Phantom Study at 1.5 and 3 Tesla

MRI tissue contrast is not well preserved at high field. In this work, we used a phantom with known, intrinsic contrast (3.6%) for model tissue pairs to test the effects of low angle refocusing pulses and magnetization transfer from adjacent slices on intrinsic contrast at 1.5 and 3 Tesla. Only T1-weighted spin echo sequences were tested since for such sequences the contrast loss, tissue heatin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 54 3  شماره 

صفحات  -

تاریخ انتشار 2005