Silicon Matrix Calcium Phosphate as a Bone Substitute: Early Clinical and Radiological Results in a Prospective Study With 12-Month Follow-up

نویسندگان

  • Luiz Pimenta
  • Carlos Fernando Arias Pesántez
  • Leonardo Oliveira
چکیده

INTRODUCTION Autograft has been the "gold standard" for orthopedic bone grafting applications, but with some clinical challenges. Here we present the rationale and clinical outcomes supporting the use of a bone substitute material that consists of a mixture of two calcium phosphates (HA and ß-TCP), which are integrated into a silicon xerogel matrix, promoting nanocrystalline apatite layers on the surface of the material following implantation into a physiological environment. METHODS Twenty-four patients with a median age of 53.80 (36-81) years underwent lumbar spinal fusion for degenerative disease, selected by clinical presentation, X-rays, and MRI findings. Subjects were evaluated preoperatively and postoperatively at 1, 3, 6, and 12 months. The outcome assessment consisted of visual analog scale (VAS), Oswestry Disability Index (ODI), and radiological assessment analyzing the state of fusion on X-ray and CT evaluation by 3 independent radiologists. RESULTS All patients completed 12-month follow-up. The mean VAS decreased from 9.3 (± 0.9) to 2.4 (± 1.6) and the mean ODI decreased from 55.0 (± 9.2) to 19.3 (± 11.4) at 12-month follow-up. Three months after surgery, 10 patients (41.67%) had solid fusion based on analysis of CT scans and dynamic radiographs. At 6 months postoperatively, the fusion rate had increased to 75% (18 patients). Twelve months after surgery, 95.83% of patients had solid fusion (23 patients). CONCLUSIONS The clinical results from this study of silicon matrix calcium phosphate are consistent with previous in vitro studies indicating that this material stimulates formation of a bioactive layer and provides an effective bone graft material for lumbar fusion applications. In comparison with previous studies involving rhBMP-2, silicon matrix calcium phosphate provided a lower fusion rate at 3- and 6-month follow-up points, but after 12 months, the fusion rate was similar, with no statistical differences and lower overall costs. No clinically relevant adverse events were associated with either the cage or graft material. With increasing evidence of high rates of enhanced fusion development in this spinal application, additional research is encouraged, including longer periods of followup, to further confirm the efficacy of silicon matrix calcium phosphate as a safe and effective bone graft substitute.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of outcomes and safety of using hydroxyapatite granules as a substitute for autograft in cervical cages for anterior cervical discectomy and interbody fusion

Background:   After cervical discectomy, autogenetic bone is packed into the cage to increase the rate of union between adjacent vertebral bodies, but donor site–related complications can still occur. In this study we evaluate the use   of hydroxyapatite granules as a substitute for autograft for interbody fusion.     Methods:   From November 2008 to November 2011, 236 patients participated in ...

متن کامل

Evaluation of Compressive Mechanical Properties of the Radial Bone Defect Treated with Selected Bone Graft Substitute Materials in Rabbit

Objective- To determine the effect of selected bone graft on the compression properties of radialbone in rabbit.Design- Experimental in vivo study.Animals- A total of 45 adult male New Zealand white rabbits.Procedures- The rabbits were anesthetized and a one-cm-full thickness piece of radial bone wasremoved using oscillating saw in the all rabbit. The rabbits were divided into 5 groups on theba...

متن کامل

The use of a biphasic calcium phosphate in a maxillary sinus floor elevation procedure: a clinical, radiological, histological, and histomorphometric evaluation with 9- and 12-month healing times

BACKGROUND This study evaluates the clinical, radiological, histological, and histomorphometric aspects of a fully synthetic biphasic calcium phosphate (BCP) (60% hydroxyapatite and 40% ß-tricalcium phosphate), used in a human maxillary sinus floor elevation (MSFE) procedure with 9- and 12-month healing time. METHODS A unilateral MSFE procedure, using 100% BCP, was performed in two series of ...

متن کامل

بررسی اثر استروژن کانژوگه بر کلسیم و فسفات سرم و ادرار در پیشگیری و درمان استئوپوروز پس از یائسگی

To evaluate the tolerance and effectiveness of conjugated Estrogen for women with established post-menopausal Osteoporosis and hot flushes, with the use of paired comparison, randomized, we tested during an 10 month period the bone mineral contents and plasma glucose in subjects who afforded by premarin in dosages of 0.625 mg for days 1 to 25 and oral medroxy progesterone acetate for days 15 to...

متن کامل

Combination of bone marrow derived cells transplantation and high tibial osteotomy in early osteoarthritis of knee: A preliminary study

Purpose: high tibial osteotomy (HTO) is a recommended treatment for medial compartment knee osteoarthritis. Newer cartilage regenerative procedures may add benefits to the result of HTO. In this prospective study we investigate safety and also results of HTO associated with bone marrow derived cells (BMDC) transplantation in relatively young and middle aged active individuals with early osteoar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2008