Development and validation of effective real-time and periodic interinstrument comparison method for automatic hematology analyzers.

نویسندگان

  • Sang Hyuk Park
  • Chan-Jeoung Park
  • Mi-Jeong Kim
  • Mi-Ok Choi
  • Min-Young Han
  • Young-Uk Cho
  • Seongsoo Jang
چکیده

OBJECTIVES We developed and validated an interinstrument comparison method for automatic hematology analyzers based on the 99th percentile coefficient of variation (CV) cutoff of daily means and validated in both patient samples and quality control (QC) materials. METHODS A total of 120 patient samples were obtained over 6 months. Data from the first 3 months were used to determine 99th percentile CV cutoff values, and data obtained in the last 3 months were used to calculate acceptable ranges and rejection rates. Identical analyses were also performed using QC materials. Two instrument comparisons were also performed, and the most appropriate allowable total error (ATE) values were determined. RESULTS The rejection rates based on the 99th percentile cutoff values were within 10.00% and 9.30% for the patient samples and QC materials, respectively. The acceptable ranges of QC materials based on the currently used method were wider than those calculated from the 99th percentile CV cutoff values in most items. In two-instrument comparisons, 34.8% of all comparisons failed, and 87.0% of failed comparisons were successful when 4 SD was applied as an ATE value instead of 3 SD. CONCLUSIONS The 99th percentile CV cutoff value-derived daily acceptable ranges can be used as a real-time interinstrument comparison method in both patient samples and QC materials. Applying 4 SD as an ATE value can significantly reduce unnecessarily followed recalibration in the leukocyte differential counts, reticulocytes, and mean corpuscular volume.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Constrained Controller Design for Real-time Delay Recovery in Metro Systems

This study is concerned with the real-time delay recovery problem in metro loop lines. Metro is the backbone of public transportation system in large cities. A discrete event model for traffic system of metro loop lines is derived and presented. Two effective automatic controllers, linear quadratic regulator (LQR) and model predictive controller (MPC), are used to recover train delays. A newly-...

متن کامل

Peykan check, a simple continuous quality control method for hematology analyzers

A simple inexpensive con!nuous quality control method, by means of eight basic blood coun!ng parameters, obtained from automated hematology analyzers, using pa!ent samples, is described. A few samples with low, normal and high values were selected and introduced to the instrument early in the morning as the first count, the results of which are plo#ed on the appropriate chart as dots. The sa...

متن کامل

Development and Validation of a Terbium-Sensitized Luminescence Analytical Method for Deferiprone

A sensitive fluorometric method for the determination of deferiprone (DFP) based on the formation of a luminescent complex with Tb3+ ions in aqueous solutions is reported. The maximum excitation and emission wavelengths were 295 and 545 nm, respectively. The effects of various factors on the luminescence intensity of the system were investigated and optimized, then under the optimum conditions,...

متن کامل

Development and Validation of a Terbium-Sensitized Luminescence Analytical Method for Deferiprone

A sensitive fluorometric method for the determination of deferiprone (DFP) based on the formation of a luminescent complex with Tb3+ ions in aqueous solutions is reported. The maximum excitation and emission wavelengths were 295 and 545 nm, respectively. The effects of various factors on the luminescence intensity of the system were investigated and optimized, then under the optimum conditions,...

متن کامل

Development of TaqMan Duplex Real-time PCR for Simultaneous Detection of Chlamydia Trachomatis and Mycoplasma Genitalium

Background and Objective: Sexually infections transmitted by bacteria are one of thetherapeutic and social problemsworldwide. The Real-time PCR assay is one of the most sensitive diagnostic and screening methods for these infections. The purpose of this study wassimultaneous detection of Chlamydia trachomatis and Mycoplasma genitaliumusing the TaqMan duplex real-time polymerase chain reaction. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 142 6  شماره 

صفحات  -

تاریخ انتشار 2014