Contribution of tibiofemoral joint contact to net loads at the knee in gait.

نویسندگان

  • Jonathan P Walter
  • Nuray Korkmaz
  • Benjamin J Fregly
  • Marcus G Pandy
چکیده

Inverse dynamics analysis is commonly used to estimate the net loads at a joint during human motion. Most lower-limb models of movement represent the knee as a simple hinge joint when calculating muscle forces. This approach is limited because it neglects the contributions from tibiofemoral joint contact forces and may therefore lead to errors in estimated muscle forces. The aim of this study was to quantify the contributions of tibiofemoral joint contact loads to the net knee loads calculated from inverse dynamics for multiple subjects and multiple gait patterns. Tibiofemoral joint contact loads were measured in four subjects with instrumented implants as each subject walked at their preferred speed (normal gait) and performed prescribed gait modifications designed to treat medial knee osteoarthritis. Tibiofemoral contact loads contributed substantially to the net knee extension and knee adduction moments in normal gait with mean values of 16% and 54%, respectively. These findings suggest that knee-contact kinematics and loads should be included in lower-limb models of movement for more accurate determination of muscle forces. The results of this study may be used to guide the development of more realistic lower-limb models that account for the effects of tibiofemoral joint contact at the knee.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In Vivo Knee Contact Force Prediction Using Patient-Specific Musculoskeletal Geometry in a Segment-Based Computational Model.

Segment-based musculoskeletal models allow the prediction of muscle, ligament, and joint forces without making assumptions regarding joint degrees-of-freedom (DOF). The dataset published for the "Grand Challenge Competition to Predict in vivo Knee Loads" provides directly measured tibiofemoral contact forces for activities of daily living (ADL). For the Sixth Grand Challenge Competition to Pred...

متن کامل

Effect of different walking speed on the gait kinematics of individuals with knee varus

The purpose of current study was to investigate the spatio-temporal gait parameters and knee varus angle during walking at different speeds in young with knee varus. 18 subjects with varus deformity classified at grade 3 of bowleg and 17 healthy subjects, volunteered to participate in this study. The following variables include stance, swing, double support and cycle time, cadence, stride le...

متن کامل

The Effect of High Heel Shoes on Tibiofemoral and Patellofemoral joint Contact Forces and Muscle Forces

Introduction: High heel shoes affect the knee joint and can cause arthritis in the tibiofemoral (TFJ) and patellofemoral joints (PFJ). There is a dearth of research investigating the contact forces of TFJ and PFJ. Therefore, the purpose of this study was to assess the effect of high heel shoes on muscle forces as well as TFJ, and PFJ contact forces during walking.   Materials & Methods: A tot...

متن کامل

Knee joint loading in forward versus backward pedaling: implications for rehabilitation strategies.

OBJECTIVE To use forward dynamic simulations of forward and backward pedaling in order to determine whether backward pedaling offers theoretical advantages over forward pedaling to rehabilitate common knee disorders.DESIGN. A comparison of knee joint loads was performed during forward and backward pedaling.BACKGROUND. Pedaling has been shown to be an effective rehabilitation exercise for a vari...

متن کامل

A real-time topography of maximum contact pressure distribution at medial tibiofemoral knee implant during gait: Application to knee rehabilitation

Knee contact pressure is a crucial factor in the knee rehabilitation programs. Although contact pressure can be estimated using finite element analysis, this approach is generally time-consuming and does not satisfy the real-time requirements of a clinical set-up. Therefore, a real-time surrogate method to estimate the contact pressure would be advantageous. This study implemented a novel compu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic research : official publication of the Orthopaedic Research Society

دوره 33 7  شماره 

صفحات  -

تاریخ انتشار 2015