Metallic nanoparticles irradiated by low-energy protons for radiation therapy: Are there significant physical effects to enhance the dose delivery?

نویسندگان

  • Anne-Catherine Heuskin
  • Bernard Gallez
  • Olivier Feron
  • Philippe Martinive
  • Carine Michiels
  • Stéphane Lucas
چکیده

PURPOSE To identify which physical properties of nanoparticles are correlated with the survival fraction of cells exposed in vitro to low-energy protons in combination with nanoparticles. METHODS The Geant4 simulation toolkit (version 10.3) was used to model nanoparticles of different sizes (5-50 nm) and materials (Ti, Zr, Hf, Ta, Au, Pt), with or without an organic capping ensuring biocompatibility and to irradiate them with 1.3 or 4 MeV protons and 5.3 MeV alpha particles. The spectra of secondary electrons inside and at the nanoparticle surface were computed, as well as electron yields, Auger and organic capping contribution, trapping in metal bulk and linear energy transfer profiles as a function of distance from the nanoparticle center. In a next step, an in silico cell model was designed and loaded with gold nanoparticles, according to experimental uptake values. Dose to the cell was evaluated macroscopically and microscopically in 100 × 100 × 100 nm³ voxels for different radiation qualities. RESULTS The cell geometry showed that radiation enhancement is negligible for the gold concentration used and for any radiation quality. However, when the single nanoparticle geometry is considered, we observed a local LET in its vicinity considerably higher than for the water equivalent case (up to 5 keV/μm at the titanium nanoparticle surface compared to 2.5 keV/μm in the water case). The yield of secondary electrons per primary interaction with 1.3 MeV protons was found to be most favorable for titanium (1.54), platinum (1.44), and gold (1.32), although results for higher Z metals are probably underestimated due to the incomplete simulation of de-excitation cascade in outer shells. It was also found that the organic capping contributed mostly to the production of low-energy electrons, adding a spike of dose near the nanoparticle surface. Indeed, the yield for the coated gold nanoparticle increased to 1.53 when exposed to 1.3 MeV protons. Although most electrons are retained inside larger nanoparticles (50 nm), it was shown that their yield is comparable to smaller sizes and that the linear energy transfer profile is better. From a combination of ballistic and nanoparticle size factors, it was concluded that 10-nm gold nanoparticles were better inducers of additional cell killing than 5-nm gold nanoparticles, matching our previous in vitro study. CONCLUSIONS Although effects from a physical standpoint are limited, the high linear energy transfer profile at the nanoparticle surface generates detrimental events in the cell, in particular ROS-induced damage and local heating.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of The Relation Between Energy Of Primary Protons And Undesired Neutron Dose During Proton Therapy By Monte Carlo Method

Introduction: High-energy beams of protons offer significant advantages for the treatment of deepseated local tumors. Their physical depth-dose distribution in tissue is characterized by a small entrance dose and a distinct maximum -Bragg peak- near the end of range with a sharp fall-off at the distal edge. Alongside its advantages there are some point that they need to meticul...

متن کامل

Evaluation of the dose and flux of secondary particles in the lung tissue in breast proton therapy using the Monte Carlo simulation code

Unlike proton therapy, conventional radiation therapy directs X-rays not only at the tumor but also unavoidably at nearby healthy tissue. Protons deliver radiation to tumor tissue while the healthy structures will be spared during proton therapy. When protons travel through matter, secondary particles like neutrons and photons are produced. It is believed that the secondary dose can lead to sec...

متن کامل

A comparison of arrived dose to the heart in the treatment of breast cancer in different modes of proton radiation by proton therapy using Monte Carlo simulation

Introdution: Today, the Advantages of radiation therapy by charged particles is indicated for the treatment of cancerous. During the passing of proton beam in the body tissues, secondary particles produce, which penetrate to the body healthy tissues and cause damage. The aim of this research was calculating the Spread out Bragg Peak for covering the breast cancer and investigating arrived dose ...

متن کامل

Role of low level laser in ameliorating the damaging effects of gamma irradiation on mice liver

Background: Exposure to ionizing radiation is inevitable. Using of low-level laser therapy (LLLT) stimulates tissue repair and reduces inflammation. The objective of the present study aimed at evaluating the therapeutic efficacy of Helium-Neon (He-Ne) laser in stimulating the reparative processes in the liver of mice after whole body gamma-irradiation (WBγ-I). Materials and Methods: Two hundred...

متن کامل

Consider potential of gold nanoparticles with proton therapy compared with KV and MEV X-ray therapy.

Introduction: Many study shown the effectiveness dose enhancement with gold nanoparticles (GNPs), especially with low-energy x-rays. Recently, proton beam radiation therapy (PBRT) has attention as a treatment for tumors. The advantage in PBRT, which releases high dose at the controllable Bragg peak position that localized for Au target and the released dose increased in depth....

متن کامل